Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M & M EXTERIORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M & M EXTERIORS in 33 GOODMAN STREET, ROCHESTER, NY 14604 (NAICS 238160). OSHA activity number 337946628.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & M Exteriors — free Get an email when a new federal OSHA severe-injury report for M & M Exteriors is published. One employer, no account, unsubscribe in one click.
Establishment
M & M EXTERIORS
Site address
33 GOODMAN STREET
City
ROCHESTER
State
NY
ZIP
14604
Mailing
2657 NORTON STREET, ROCHESTER, NY 14609
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 1, 2013
Penalty
Initial $2,800 · Current $750 Reduced
29 CFR 1926.501(b)(10):     Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety nets, or warning line systems and safety monitoring or personal fall arrest system.     (a)  On or  about 12/19/12, while performing roofing work on 33 Goodman Street, in Rochester, New York, workers were not protected against falls with conventional fall arrest systems.    ABATEMENT CERTIFICATION NOT REQUIRED
Recent events (2)
  • — I (S) $750
  • — Z (S) $2800

1926.501 B11

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(11):     Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:      (a)  On or  about 12/19/12, while performing roofing work on 33 Goodman Street, in Rochester, New York, workers were not protected against falls with conventional fall arrest systems.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2013
Penalty
Initial $2,040 · Current $750 Reduced
29 CFR 1926.1053(b)(1):     Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet  above the upper landing surface to which the ladder was used to gain access:      (a)  On or  about 12/19/12, while performing roofing work on 33 Goodman Street, in Rochester, New York, a portable ladder in use was not extended 3 feet above the landing access point.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $750
  • — Z (S) $2040

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337946628.