Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED SOLUTIONS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of UNITED SOLUTIONS in INDUSTRIAL DRIVE, SARDIS, MS 38666 (NAICS 326199). OSHA activity number 338004013.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Solutions — free Get an email when a new federal OSHA severe-injury report for United Solutions is published. One employer, no account, unsubscribe in one click.
Establishment
UNITED SOLUTIONS
Site address
INDUSTRIAL DRIVE
City
SARDIS
State
MS
ZIP
38666
Mailing
INDUSTRIAL DRIVE, SARDIS, MS 38666
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
55
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 29, 2013
Abate by
Mar 18, 2013
Penalty
Initial $2,363 · Current $1,418 Reduced
29 CFR 1910.147(c)(4)(ii)(B):     The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    (a) Plastic Line - On or about December 11, 2012 specific lockout procedures had not been developed for employees working on injection molding machines on plactic line.
Recent events (2)
  • — I (S) $1417.8
  • — Z (S) $2363

1910.303 F02

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 29, 2013
Abate by
Feb 25, 2013
Penalty
Initial $1,418 · Current $851 Reduced
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    (a) Front, Office - On or about December 11, 2012 circuit breaker lectrical panel controling office power was not labeled.
Recent events (2)
  • — I (S) $850.8
  • — Z (S) $1418

1910.146 C03

Other-than-serious 1 instance 10 exposed
Issued
Jan 29, 2013
Abate by
Mar 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(3):     When the employer decided that its employees would not enter permit spaces, the employer did not comply with 29 CFR 1910.146(c)(1), 29 CFR 1910.146(c)(2), 29 CFR 1910.146(c)(6), and 29 CFR 1910.146(c)(8:    (a) Vessells, Outside - On or about December 7, 2012 the employer failed to evaluate the workplace and post the signs indicating the vessels containing propylene pellets as a confined space.
Recent events (2)