ENFIELD, CT —
OSHA Inspection: ATLANTIC WOODCRAFT, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ATLANTIC WOODCRAFT, INC. in 199 MOODY ROAD, ENFIELD, CT 06082 (NAICS 337110). OSHA activity number 338004617.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ATLANTIC WOODCRAFT, INC.
- Site address
- 199 MOODY ROAD
- City
- ENFIELD
- State
- CT
- ZIP
- 06082
- Mailing
- 199 MOODY ROAD, ENFIELD, CT 06082
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 19
- Ownership type
- A
Citations
22 citations on file for this inspection.
1910.106 D02 III
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.106(d)(2)(iii): Flammable liquid containers were not in accordance with Table H-12: Spray Room: On, or about, December 21, 2012, Fast Thinner, a Category 2 flammable liquid, was used to clean spray guns and related equipment over a pink, plastic pail. It had an estimated liquid volume of two gallons and was approximately half full, which exceeded the container sizes allowed in Table H-12 of 29 CFR 1910.106. Table H-12 allowed up to one quart of a Category 2 flammable liquid in approved plastic containers.
Recent events (3)
- — F (S) $1200
- — C (S) $2000
- — Z (S) $2000
1910.107 E01
- Issued
- Mar 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(1): The storage of flammable liquids or liquids with a flashpoint greater than 199.4 F (93 C) in connection with spraying operations did not conform to the requirements of 29 CFR 1910.106: Spray Room: On, or about, December 21, 2012, over 120 gallons of Category 2, 3 and 4 flammable paints, stains and thinners were stored in the open room next to the spray booth. Ref. 29 CFR 1910.106(e)(2)(ii)(b)(2)
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 E02
- Issued
- Mar 14, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 F (93 C) kept in the vicinity of spraying operations was not the minimum required for operations and exceeded a supply for 1 day or one shift: Spray Room: On, or about, December 21, 2012, in excess of 120 gallons of Category 2, 3 and 4 flammable paints, stains and thinners were stored in the open room next to the spray booth. The room was not provided with a roof and the door was left open during the work shift.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.106 E02 IV A
- Issued
- Mar 14, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 F (37.8 C), were not kept in covered containers when not actually in use: Spray Room: On, or about, December 21, 2012, various containers of flammable liquids were left uncovered throughout the work area. A pink plastic pail that contained Fast Thinner 246092, a Category 2 flammable liquid, used to clean paint guns and equipment was left uncovered on a workbench and containers with flammable liquid residue were left uncovered in the work area to dry out before disposal.
Recent events (3)
- — F (S) $1200
- — C (S) $2000
- — Z (S) $2000
1910.107 E04
- Issued
- Mar 14, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(4): The filling of containers, including portable mixing tanks, was not done only in a suitable mixing room(s) or in a spraying area when the ventilating system was in operation: Spray Room: On, or about, December 21, 2012, paint mixing operations and cleaning of paint guns and related equipment were done on work benches in the general work area.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 B05 I
- Issued
- Mar 14, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity was maintained: Spray Room: On, or about, December 21, 2012, a visible gauge or alarm had not been installed on the spray booth.
Recent events (3)
- — F (S) $720
- — C (S) $1200
- — Z (S) $1200
1910.107 G02
- Issued
- Mar 14, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes were not of nonsparking material: Spray Booth: On, or about December 21, 2012, an excessive amount of overspray had accumulated on the interior surfaces of the spray booth and behind the dry filters. Also, a non spark-resistant steel shovel had been provided to scrape and clean the interior spray booth surface.
Recent events (3)
- — F (S) $720
- — C (S) $1200
- — Z (S) $1200
1910.107 C09 I
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.107(c)(9)(i): All metal parts of spray booths, exhaust ducts, and piping systems conveying flammable liquids or liquids with a flashpoint greater than 199.4 F (93 C) or aerated solids were not properly electrically grounded in an effective and permanent manner: Spray Booth: On, or about, December 21, 2012, the Binks air spray gun used to apply flammable paints and stains was not grounded to the spray booth or other suitable building surface to prevent the build-up of static electricity on the gun.
Recent events (3)
- — F (S) $1680
- — C (S) $2800
- — Z (S) $2800
1910.107 D12
- Issued
- Mar 14, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(d)(12): Freshly sprayed articles were not dried only in spaces provided with adequate ventilation to prevent the formation of explosive vapors or when adequate and reliable ventilation was not provided such drying spaces did not conform to the requirements of a spraying area: Spray Room: A drying rack was installed on the wall in the spray room to store freshly sprayed items while they dried. A live wall mounted receptacle was located next to the rack and in close proximity to freshly sprayed pieces.
Recent events (3)
- — F (S) $1200
- — C (S) $2000
- — Z (S) $2000
1910.107 G03
- Issued
- Mar 14, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(3): Approved metal waste cans were not provided wherever rags or waste were impregnated with finishing material and all such rags or waste were not deposited therein immediately after use: Spray Room: Adequate receptacles had not been provided for the proper disposal of rags that had been used with flammable solvents, stains and thinners. Rags were stored in open containers or in piles on workbenches.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.132 D01
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: Shop: On, or about, February 27, 2013, the employer had not conducted a personal protective equipment hazard assessment to determine what operations in the shop required the use of personal protective equipment. Employees used powered woodworking equipment and portable tools and worked with solvents such as paint stains and thinners.
Recent events (3)
- — F (S) $1200
- — C (S) $2000
- — Z (S) $2000
1910.133 A01
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: Shop: On, or about, December 21, 2012, an employee was who used powered woodworking equipment and compressed air for cleaing was wearing regular street glasses that were not approved as safety glasses.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Spray Room: On, or about, December 21, 2012, the employer had not developed and implemented a written Respiratory Protection program to cover the selection, use and maintenance of respirators used in the shop. An employee was required to wear a Sperian half-mask, cartridge respirator while conducting spray painting operations.
Recent events (3)
- — F (S) $720
- — C (S) $1200
- — Z (S) $1200
1910.134 E01
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee(s) ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Spray Room: On, or about, December 21, 2012, an employee who was required to wear a Sperian half-mask, cartridge respirator while conducting spray painting operations had not been medically evaluated to determine if he was physically able to wear a respirator.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.213 D01
- Issued
- Mar 14, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Shop Area: On, or about, December 21, 2012, the following Model 53480 Saw Stop table saws were not used with hood guards: A. Table Saw serial number 1081001349. B. Table Saw serial number 07329095.
Recent events (3)
- — F (S) $720
- — C (S) $1200
- — Z (S) $1200
1910.213 S06
- Issued
- Mar 14, 2013
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards: Panel Saw Area: On, or about, December 21, 2012, wood scrap and debris was allowed to accumulate around the Schelling FN6 panel saw creating tripping hazards and blocking the proper operation of an emergency stop foot bar.
Recent events (3)
- — F (S) $612
- — C (S) $1020
- — Z (S) $1020
1910.307 C
- Issued
- Mar 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: Shop: On, or about, December 21, 2012, combustible wood dust had accumulated on an 120 volt/208 volt overhead electrical buss bar that served woodworking equipment in the shop. The buss bar was not rated for use in a Class II locatation where combustible dust could accumulate on or in the electrical enclosures.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Shop: On, or about, February 27, 2013, the employer had not developed and implemented a Hazard Communication program to provide employees with information and training regarding the safe use of chemicals used in the shop. Employees used flammable solvents, stains and thinners in the spray finishing department. Also, a container of paint stripper that contained methylene chloride, a carcinogen, was also stored in the spray finishing area for a completed order that required objects to be refinished.
Recent events (3)
- — F (S) $1200
- — C (S) $2000
- — Z (S) $2000
1910.1200 F05 I
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: Spray Room: On, or about, December 21, 2012, a plastic squeeze bottle and a pink plastic pail both containing Fast Thinner 246092, a Category 2 flammable liquid, were not labeled to indicate the identity of the contents.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 F05 II
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: Spray Room: On, or about, December 21, 2012, a plastic squeeze bottle and a pink plastic pail, both containing Fast Thinner 246092, a Category 2 flammable liquid, were not provided with an appropriate hazard warning.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.38 B
- Issued
- Mar 14, 2013
- Abate by
- Jul 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: Office and Shop: On, or about, March 6, 2013, the employer had not developed and implemented a written emergency action plant in case of a fire or other emergency in the building.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.106 D05 I
- Issued
- Mar 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(5)(i): Flammable liquids, including stock for sale, was stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people: Back Room: On, or about, December 21, 2012, a fifty-five gallon drum of Fast Thinner 246092, a Category 2 flammable liquid, was stored next to an exit door.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Atlantic Woodcraft, INC.
View Atlantic Woodcraft, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338004617.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.