OSHA Inspection: BECKER BOILER CO., INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of BECKER BOILER CO., INC. in 2157 S 1ST STREET, MILWAUKEE, WI 53207 (NAICS 332312). OSHA activity number 338018617.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Becker Boiler CO., INC. for free Get an email when a new federal OSHA severe-injury report for Becker Boiler CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
2157 S 1ST STREET
City
MILWAUKEE
State
WI
ZIP
53207
Mailing
1785 E. BOLIVAR AVENUE, SAINT FRANCIS, WI 53235
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
6
Ownership type
Private (A)

3 citations on file for this inspection.

1910.106 E02 II

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 5, 2013
Abate by
Mar 11, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.106(e)(2)(ii):  Flammable or combustible liquids were not stored in tanks or closed containers:    (a)    In the painting area the paint thinner used for soaking the spray guns was not in a closed container.
Recent events (2)
  • · I (S) $1600
  • · Z (S) $1600

1910.107 G02

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 5, 2013
Abate by
Mar 11, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.107(g)(2):     All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:    (a)    The painting area, where the Sherwin Williams Shopcoat red and grey primers are sprayed onto parts laying on the floor, was not cleaned after the previous day's painting.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1600

1910.107 G07

Other-than-serious 1 instance 6 exposed
Issued
Mar 5, 2013
Abate by
Mar 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(7):    "No smoking" signs in large letters on contrasting color backgrounds were not conspicuously posted at all spraying areas and the paint storage rooms:     (a)     There was no "no smoking" sign posted in the painting area where the Sherwin Williams Shopcoat red and grey primers were sprayed.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Becker Boiler CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338018617.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.