SAN ANTONIO, TX —
OSHA Inspection: KELLER CUSTOM SIGNS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KELLER CUSTOM SIGNS in 1234 SAN FRANCISCO, SAN ANTONIO, TX 78201 (NAICS 339950). OSHA activity number 338022619.
Where did this inspection happen?
- Establishment
- KELLER CUSTOM SIGNS
- Site address
- 1234 SAN FRANCISCO
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78201
- Mailing
- 1234 SAN FRANCISCO, SAN ANTONIO, TX 78201
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339950
- Employees
- 18
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fall hazard of approximately 14 feet. On or about 12/27/2012, an employee was exposed to a fall of approximately 14 feet while standing on the forks of a forklift to unscrew and screw metal siding on the building.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.253 B04 I
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or in an acetylene generator compartment: On or about 12/27/2012, employees were exposed to a struck-by hazard when acetylene and oxygen cylinders were stored within inches of each other in the maintenance cage.
Recent events (2)
- — I (S) $1680
- — Z (S) $2400
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about 12/27/2012, employees were exposed to an electrical shock hazard when a temporary (extension) cord was used in place of a permanent wire for the deep freeze unit.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
More inspections in this industry (NAICS 339950)
APEX, NC—2026-07-07
161498 - SEVEN SPRINGS, INC.
MINNEAPOLIS, MN—2026-06-30
111500 - SIGNMINDS INC
ANGIER, NC—2026-06-29
161462 - CAROLINA SIGN AND SERVICE, LLC
GREENE, NY—2026-06-17
RAPP SIGNS, INC.
LEXINGTON, KY—2026-06-11
69225 - INTEGRATED SIGN - GRAPHIC INC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338022619.