EAU CLAIRE, WI —
OSHA Inspection: LPI INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LPI INC. in 4404 ANDERSON DRIVE, EAU CLAIRE, WI 54703 (NAICS 333999). OSHA activity number 338025414.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LPI INC.
- Site address
- 4404 ANDERSON DRIVE
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54703
- Mailing
- 4404 ANDERSON DRIVE, EAU CLAIRE, WI 54703
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 37
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Apr 1, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): a) Throughout the production area; The lockout-tagout procedures were not complete and did not clearly and specifically outline the scope, purpose, authorization, rules and techniques to be used for the effective control of hazardous energy for equipment such as but not limited to, MAZAK Optiplex 3015, HEM band saw and the vacuum lift.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.147 C06 I
- Issued
- Apr 1, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Throughout the production area; The employer did not perform periodic audits of the lockout tagout machine specific procedures on an at least annual basis.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Apr 1, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Throughout the production area; The employees would perform cleaning of the Mazak Optiplex without affixing a lockout or tagout device in order to isolate the energy.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at LPI INC.
View LPI INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338025414.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.