OSHA Inspection: GREENWOOD ICE CREAM COMPANY, LTD.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GREENWOOD ICE CREAM COMPANY, LTD. in 4829 PEACHTREE RD., CHAMBLEE, GA 30341 (NAICS 311520). OSHA activity number 338034218.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Greenwood ICE Cream Company, LTD. — free Get an email when a new federal OSHA severe-injury report for Greenwood ICE Cream Company, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
4829 PEACHTREE RD.
City
CHAMBLEE
State
GA
ZIP
30341
Mailing
4829 PEACHTREE RD., CHAMBLEE, GA 30341
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311520
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.24 B

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 13, 2013
Abate by
Apr 22, 2013
Penalty
Initial $1,020 · Current $600 Reduced
29 CFR 1910.24(b):     Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations:    a) Plant, Tanker Bay Area - Employees accessed the tank platform situated at an elevation of 3.0 ft. 10 in., and the employer did not provide/install a fixed stair.        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $600
  • — Z (S) $1020

1910.303 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 13, 2013
Abate by
May 22, 2013
Penalty
Initial $1,360 · Current $1,100 Reduced
29 CFR 1910.305(e)(1):     Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in wet locations were not weatherproof:    a) Plant, Production Area - The facility had batch freezers and four continuous freezers for the production of ice cream. At the time of the current inspection, one of the continuous freezers was disabled due to repairs and only three were in operation.  At the end of the shift employees conducted cleaning/sanitation of the continuous freezers with water hoses. The electrical components including (but not limited to) the junction boxes mounted on the ceiling above the in the ceiling and the boxes and switches on the wall were not waterproof.      b) Plant, Mixing/Pasteurizing Area - Employees conducted cleaning/sanitation of the equipment with water hoses, and the electrical components including (but not limited to) the junction boxes in the ceiling and the boxes and switches on the wall were not waterproof.      Or in the alternative:     29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Plant, Production Area - Employees conducted cleaning/sanitation of the continuous freezers with water hoses, and the electrical components including (but not limited to) the junction boxes in the ceiling and the boxes and switches on the wall were not waterproof.      b) Plant, Mixing/Pasteurizing Area - Employees conducted cleaning/sanitation of the equipment with water hoses, and the electrical components including (but not limited to) the junction boxes in the ceiling and the boxes and switches on the wall were not waterproof.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1360

1910.22 A01

Other-than-serious 3 instances 2 exposed
Issued
Mar 13, 2013
Abate by
May 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a) Plant, Production Area - The concrete floor presented uneven surface, cracks and holes, and was not repaired.    b) Plant, Production Area - The freezer door did not close completely, and ice (from moisture condensation) was not removed from the floor.     c) Plant, Mixing/Pasteurizing Area - The concrete floor presented uneven surface, cracks and holes, and was not repaired.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Greenwood ICE Cream Company, LTD.'s full OSHA safety record →