Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VOLTAIX INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VOLTAIX INC. in 197 MEISTER AVE., BRANCHBURG, NJ 08876 (NAICS 325120). OSHA activity number 338046410.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Voltaix INC. — free Get an email when a new federal OSHA severe-injury report for Voltaix INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VOLTAIX INC.
Site address
197 MEISTER AVE.
City
BRANCHBURG
State
NJ
ZIP
08876
Mailing
197 MEISTER AVE., SOMERVILLE, NJ 08876
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325120
Employees
150
Ownership type
A

1 citation on file for this inspection.

1910.101 B

Other-than-serious 1 instance 1 exposed
Issued
Apr 12, 2013
Abate by
May 8, 2013
Penalty
Initial $3,825 · Current $1,912 Reduced
29 CFR 1910.101(b):  1910.101(b):  In-plant handling, storage and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks shall be in accordance with Compress Gas Association Pamphlet P1-1965:    a/  Voltaix/Branchburg NJ site: TSA Reactor Cleaning Area- Approx. 16 TSA Reactors   1/ Pressure-regulating devices were not provided where Helium is used to purge gas(es) from the TSA reactors that were being prepared for cleaning.  Means were not provided on each Reactor to ensure that the Reactors were adequately purged prior to the cleaning operator.    2/ When tools are used to remove salt, (solidified by-product) containing gases from the TSA Reactors, some of the tools used were not designed specifically for the operation. Means were not provided to ensure that all of the cleaning operators were provided with and used the appropriate tools.     3/ Employees using Drager Gas Meters used to detect the presence of gas during the TSA Reactor cleaning operation did not have a consistent rule to follow when action levels appeared on the meter.  Example:  When the gas meter reaches level #1, employees continue to work; when the level reaches #2, employees leave the area for 5 to 10 minutes and return without contacting a Supervisor.     Reference:  Compress Gas Association Pamphlet P1    Safe Handling of compressed Gases in Containers  Section 3.6.5 Pressure Regulators  Section 3.6.8 Manifolds Section 3.6.9 - Regulators, gauges, hoses, etc.  Section 3.6.10 Tools designed specifically for the purpose    Observed on/or about 01/03/2013.
Recent events (2)
  • — I (O) $1912
  • — Z (S) $3825

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338046410.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.