PITTSGROVE, NJ —
OSHA Inspection: COLE BROTHERS MARBLE & GRANITE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of COLE BROTHERS MARBLE & GRANITE in 892 PARVINS MILL RD, PITTSGROVE, NJ 08318 (NAICS 327991). OSHA activity number 338064017.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLE BROTHERS MARBLE & GRANITE
- Site address
- 892 PARVINS MILL RD
- City
- PITTSGROVE
- State
- NJ
- ZIP
- 08318
- Mailing
- 892 PARVINS MILL RD, PITTSGROVE, NJ 08318
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 6
- Ownership type
- A
Citations
16 citations on file for this inspection.
1910.110 F02 I
- Issued
- Apr 30, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): LP-Gas Containers were not stored in a manner to minimize exposure to excessive temperature rise, physical damange, or tampering by unauthorized persons: a) Outside behind production shop: Propane cylinders used to power the TCM forklift were not stored in a secure location or in a cool shaded area, on or about 1/3/13.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.178 L01 I
- Issued
- Apr 30, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Throughout facility: The employer did not evaluate employees competency before allowing them to operate the TCM FCG-25 forklift, on or about 1/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.178 L02 II
- Issued
- Apr 30, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) Throughout facility: The employer did not ensure that employees operating CAT forklift model 693-1, serial 920242 and TCM FCG-25 forklift, successfully completed training consisting of formal instruction, practical training and an evaluation, on or about 1/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q06
- Issued
- Apr 30, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(q)(6): Industrial trucks were altered by the addition of extra parts not provided by the manufacturer. Additional counterweighting of fork trucks was not approved by the truck manufacturer. a) Throughout facility: A boom and Abaco Lifter added to the TCM FCG-25 forklift to move pieces of marble and granite were not approved by the forklift manufacturer, on or about 1/3/13. b) Throughout facility: A Vestil Lift Master boom added to the CAT forklift model 693-1, serial 920242 to move pieces of marble and granite was not approved by the forklift manufacturer, on or about 1/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.134 E01
- Issued
- Apr 30, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Production area: The employer did not provide a medical evaluation to employees required to use Gerson half face air purifying respirators model 8311P, on or about 1/3/13.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.212 A05
- Issued
- Apr 30, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a) Production shop near overhead door: A pedestal fan model MACH30A had a broken guard with an opening more than a half inch, on or about 1/3/13.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.242 B
- Issued
- Apr 30, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Production area: Employees used compressed air guns to clean dust from product and clothing that was set at 60 psi and did not have a reducer, on or about 1/3/13.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.305 G01 IV A
- Issued
- Apr 30, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Front of shop near overhead door: An extension cord was used to power a garage door opener, on or about 1/3/13. b) Front of shop next to overhead door: An extension cord was used to power a pedestal fan, on or about 1/3/13. c) Production shop next to electrical panel: A three outlet extension cord plugged into an electrical receptacle was used to power a clock, Ryobi charger and another extension cord, on or about 1/3/13. d) Production shop next to plunge router: An extension cord was used to power an extension cord reel that powered a pedestal fan, on or about 1/3/13.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.305 G01 IV B
- Issued
- Apr 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: a) Front of production area near overhead door: An extension cord was run through the ceiling to operate the garage door opener, on or about 1/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV D
- Issued
- Apr 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
Flexible cords were attached to building surfaces: a) Front of production area near overhead door: An extension cord powering a garage door opener was attached to metal conduit, on or about 1/3/13. b) Back of production area behind bridge saw: An extension cord powering an extension cord reel that powered a pedestal fan was attached to the wall and ceiling, on or about 1/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Apr 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Production area next to bridge saw: An extension cord powering a Mr. Heater Contractor 7500 BTU space heater had a broken strain relief, on or about 1/3/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Apr 30, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Production area: The employer did not develop and implement a written respirator program for those employees required to use Gerson half face air purifying respirators model 8311P and Moldex 2200 N95 particulate dust masks, on or about 1/3/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 I
- Issued
- Apr 30, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Production area: The employer did not provide a copy of appendix D to employees using Moldex 2200 N95 filtering facepiece dust masks, on or about 1/3/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G02
- Issued
- Apr 30, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Production shop: The employer did not provide training to employees required to use fire extinguishers that familiarized them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting initially and annually thereafter, on or about 1/3/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G01
- Issued
- Apr 30, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a) Throughout facility: The employer did not provide safety data sheets for chemicals used by employees, including, but not limited to, acetone, paint thinner, Tenax mastic, Tenax hardener, propane and Goof Off, on or about 1/3/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Apr 30, 2013
- Abate by
- May 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Throughout facility: The employer did not provide information and training for the chemicals used by employees, including, but not limited to, acetone, paint thinner, Tenax mastic, Tenax hardener, propane and Goof Off, on or about 1/3/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 327991)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338064017.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.