Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M & A PROJECTS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of M & A PROJECTS INC. in 1 BALINT DRIVE, YONKERS, NY 10710 (NAICS 238140). OSHA activity number 338084015.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & a Projects INC. — free Get an email when a new federal OSHA severe-injury report for M & a Projects INC. is published. One employer, no account, unsubscribe in one click.
Establishment
M & A PROJECTS INC.
Site address
1 BALINT DRIVE
City
YONKERS
State
NY
ZIP
10710
Mailing
18 DIVISION PLACE, BROOKLYN, NY 11222
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.50 G

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 1, 2013
Abate by
Mar 8, 2013
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1926.50(g): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    Location: 1 Balint Drive Yonkers NY 10710    On or about 1/4/13,  a) Facilities for quick drenching or flushing of the eyes and body were not provided for employees mixing and using a product that contained Portland Cement.
Recent events (3)
  • — C (S) $1200
  • — F (S) $720
  • — Z (S) $1200

1926.404 B01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.     Location: 1 Balint Drive Yonkers NY 10710    On or about 1/4/13,  a) The employer did not provide a ground fault circuit interrupter or an assured equipment grounding conductor program to protect employees using electric power tools including a drill used to mix cement.
Recent events (3)
  • — C (S) $2000
  • — F (S) $1200
  • — Z (S) $2000

1926.405 B02

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2013
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.405(b)(2): In an energized installation, each outlet box did not have a cover, faceplate, or fixture canopy.    Location: 1 Balint Drive Yonkers NY 10710    On or about 1/4/13,  a) A quad box that contained a duplex outlet and snap switch did not have a faceplate.
Recent events (3)
  • — C (S) $1600
  • — F (S) $960
  • — Z (S) $1600

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support and a grasping device was not provided to assist emmployees in mounting and dismounting the ladder:    Location: 1 Balint Drive Yonkers NY 10710    On or about 1/4/13,  a) A Werner D1532-2 aluminum ladder extended approximately 18 inches above the upper landing surface.
Recent events (3)
  • — C (S) $2000
  • — F (S) $1200
  • — Z (S) $2000

1926.1053 B04

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2013
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    Location: 1 Balint Drive Yonkers NY 10710    On or about 1/4/13,  a) A Lynn AS100 Type III step ladder was used in the closed position. It was being used on a construction site and was rated for household use.
Recent events (3)
  • — C (S) $1600
  • — F (S) $960
  • — Z (S) $1600

View M & a Projects INC.'s full OSHA safety record →