TEMPLETON, MA —
OSHA Inspection: A.P. MACHINE COMPANY, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of A.P. MACHINE COMPANY, INC in 195 BROOKS RD, TEMPLETON, MA 01468 (NAICS 332710). OSHA activity number 338094014.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.P. MACHINE COMPANY, INC
- Site address
- 195 BROOKS RD
- City
- TEMPLETON
- State
- MA
- ZIP
- 01468
- Mailing
- 195 BROOKS RD, TEMPLETON, MA 01468
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.157 C04
- Issued
- Mar 29, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.157(c)(4):The employer did not assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times: (a) 195 Brooks Rd Templeton, MA: On or about November 19, 2012, of the 13 fire extinguishers observed in this facility, only 2 were charged and current with their inspection, the other 11 were either; empty (2), out of date (6) or missing from their designated place (3) which is not in accordance with this subpart.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.212 A01
- Issued
- Mar 29, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): No methods of machine guarding were provided to protect the operator from hazards such as those created by point of operation (e.g. rotating parts): (a) 195 Brooks Rd Templeton, MA: On or about November 19, 2012, employees were observed operating the following machines: A.F. 100 by Stovkis, Edera & Co. horizontal drill press Trens 71C Lathe by King Machine Tool Co without any guards at the point of operation as required by this subpart: Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.303 B02
- Issued
- Mar 29, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled equipment was not installed and/ or was not used in accordance with any instructions included in the listing or labeling: (a) 195 Brooks Rd Templeton, MA: On or about November 19, 2012, the electrical service panel did not have the cover it was designed and required to have on the panel box which is not in accordance with this subpart.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.303 F02
- Issued
- Mar 29, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not marked to indicate its purpose, unless located and arranged so the purpose is evident: (a) 195 Brooks Rd Templeton, MA: On or about November 19, 2012 the electrical service panel had none of its components marked to indicate use as required by this subpart.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Mar 29, 2013
- Abate by
- Apr 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment: (a) 195 Brooks Rd Templeton, MA: On or about November 19, 2012, the electrical service panel was blocked by various materials which is not in accordance with this subpart.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 332710)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338094014.