Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCAN-PAC MFG., INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SCAN-PAC MFG., INC. in N84 W13510 LEON ROAD, MENOMONEE FALLS, WI 53051 (NAICS 336399). OSHA activity number 338094410.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Scan-Pac MFG., INC. — free Get an email when a new federal OSHA severe-injury report for Scan-Pac MFG., INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SCAN-PAC MFG., INC.
Site address
N84 W13510 LEON ROAD
City
MENOMONEE FALLS
State
WI
ZIP
53051
Mailing
N84 W13510 LEON ROAD, MENOMONEE FALLS, WI 53051
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
100
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 1 exposed
Issued
Apr 5, 2013
Abate by
Sep 15, 2013
Penalty
Initial $5,049 · Current $3,500 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to combustible friction material dust explosion, deflagration, or other fire hazards while working at or near dust collection systems which were not adequately designed to prevent or minimize employee exposure in the event of a deflagration or other uncontrolled fire event:    a)	The two outdoor fabric filter media-type dust collectors (baghouses) used for collecting combustible friction material dust (mixture of phenolic resin, synthetic vitreous fibers, barium sulfate, graphite, calcium hydroxide, chromic oxide, iron oxide, aluminum oxide, wollastonite, magnesium oxide, talc, and zinc oxide) were not provided with a means of:    i.	Explosion protection for the main collector and secondary dust collection bin.    ii.	Fire protection for the main collector.    iii.	Deflagration (flame front) propagation protection between the outdoor dust collector units and the upstream processes.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5049

1910.132 A

Serious Gravity 5 1 instance 22 exposed
Issued
Apr 5, 2013
Abate by
Apr 11, 2013
Penalty
Initial $3,366 · Current $0 Reduced
29 CFR 1910.132(a):    Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    (a)     Employees were assigned to the dust houses to clean the dust from the dust bins at the North and South dust collectors and were exposed to the hazard of flash fires and were not required to wear flame-resistant garments.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3366

1910.22 A02

Serious Gravity 5 1 instance 22 exposed
Issued
Apr 5, 2013
Abate by
Apr 11, 2013
Penalty
Initial $3,366 · Current $1,100 Reduced
29 CFR 1910.22(a)(2):     Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    (a)     The dust house below the North dust collector had a dust accumulation on the floor that was as thick as 2 inches and exposed employees to fire and deflagration hazards.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $3366

1910.1025 D02

Other-than-serious 1 instance 1 exposed
Issued
Apr 5, 2013
Abate by
Jun 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(d)(2):    An initial determination was not made to determine if any employee may be exposed to lead at or above the action level:    (a)     Employees handle copper-zinc-lead alloy which contains 1.5% to 2.5% lead and there had been no air sampling to determine their exposure.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1048 D01 I

Other-than-serious 1 instance 1 exposed
Issued
Apr 5, 2013
Abate by
Jun 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1048(d)(1)(i):   Employees of a workplace covered by this standard were not monitored to determine their exposure to formaldehyde:    (a)     Employees handle Plenco phenolic resin and use heated presses to mold the resin were potentially exposed to formaldehyde and there had been no air monitoring to determine their exposure.