OSHA Inspection: VANQUISH CONTRACTING CORP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VANQUISH CONTRACTING CORP in 160 LEXINGTON AVE, NEW YORK, NY 10016 (NAICS 238910). OSHA activity number 338140817.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vanquish Contracting Corp — free Get an email when a new federal OSHA severe-injury report for Vanquish Contracting Corp is published. One employer, no account, unsubscribe in one click.
Site address
160 LEXINGTON AVE
City
NEW YORK
State
NY
ZIP
10016
Mailing
5602 ARNOLD AVE, MASPETH, NY 11378
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
25
Ownership type
A

5 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2013
Abate by
Apr 4, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(e)(1):     When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.      a) 3rd floor:  On or about January 8, 2013    Employees were performing demolition from mobile scaffolds but were climbing the side frames which had not been designed for such use.
Recent events (2)
  • — Z (S) $2000
  • — I (S) $1000

1926.451 F05

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2013
Abate by
Apr 4, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(f)(5):     Scaffolds shall not be moved horizontally while employees are on them, unless they have been designed by a registered professional engineer specifically for such movement or, for mobile scaffolds, where the provisions of 1926.452(w) are followed.      a) 3rd floor:  On or about January 8, 2013    Employees were performing demolition from mobile scaffolds which were moved during use.
Recent events (2)
  • — Z (S) $2000
  • — I (S) $1000

1926.501 C

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 21, 2013
Abate by
Apr 4, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.501(c):   When an employee is exposed to falling objects, the employer shall have each em[ployee wear a hardhat and shall implement one of the following measiures  1-Erect toeboards, screens, or guardrail systems to prevent objects from falling from higher levels; or  2-Erect a canopy structure and keep potential fall objects far enough from the edge of the higher level so that those objects would not go over the edge if they were accoidentally displaceds; or  3-Barricade the area to which objects could fall, prohibit employees from entering the barricaded area, and keep objects that may fall far enough away from the edge of a higher level so that those objects would not go over the edge if they were accidentally displaced.    a) 3rd floor:  On or about January 8, 2013    Demolition plans did not adequately determine the possibility of unplanned collapse while employees were perfoming demo from a scafold.
Recent events (2)
  • — Z (S) $1600
  • — I (S) $800

1926.850 A

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 21, 2013
Abate by
Apr 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.850(a):     Prior to permitting employees to start demolition operations, an engineering survey shall be made, by a competent person, of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure. Any adjacent structure where employees may be exposed shall also be similarly checked. The employer shall have in writing evidence that such a survey has been performed.    a) 3rd floor:  On or about January 8, 2013    Demolition plans did not adequately determine the possibility of unplanned collapse while employees were perfoming demo from a scafold.
Recent events (2)
  • — Z (S) $0
  • — I (S) $0

1926.859 G

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2013
Abate by
Apr 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.859(g): During demolition, continuing inspections by a competent person shall be made as the work progresses to detect hazards resulting from weakened or deteriorated floors, or walls, or loosened material. No employee shall be permitted to work where such hazards exist until they are corrected by shoring, bracing, or other effective means.    a) 3rd floor:  On or about January 8, 2013    Continuing inspections by a competent person were not performed during demolition.
Recent events (2)