MADISON, WI —
OSHA Inspection: ROOFING SPECIALIST LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROOFING SPECIALIST LLC in WEST GORHAM STREET, MADISON, WI 53703 (NAICS 238160). OSHA activity number 338157613.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROOFING SPECIALIST LLC
- Site address
- WEST GORHAM STREET
- City
- MADISON
- State
- WI
- ZIP
- 53703
- Mailing
- 159 CLARMAR DRIVE, SUN PRAIRIE, WI 53590
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1053 B12
- Issued
- Jan 30, 2013
- Abate by
- Feb 7, 2013
- Penalty
- Initial $1,760 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails: On or about January 9, 2013, employees were utilizing a conductive ladder within close proximity of an electrical source.
Recent events (2)
- — I (S) $1000
- — Z (S) $1760
1926.501 B13
- Issued
- Jan 30, 2013
- Abate by
- Feb 7, 2013
- Penalty
- Initial $4,400 · Current $2,600 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about January 9, 2013, employees working on a residential roof installing flashing and shingles at a height greater than six feet were doing so without fall protection. Roofing Specialist, LLC, was previously cited for a violation of this or its equivalent Occupational Safety and Health Standard 29 CFR 1926.501(b)(10), which was contained in OSHA Inspection Number 313129801, Citation Number 1, Item Number 1, Issued on 9/1/2009, and was affirmed final order on 10/30/2009, with respect to a workplace located at 2309 Columbus Lane, Madison, WI 53704.
Recent events (2)
- — I (R) $2600
- — Z (R) $4400
More inspections at Roofing Specialist LLC
View Roofing Specialist LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338157613.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.