PONTOTOC, MS —
OSHA Inspection: ABEL LOPEZ CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ABEL LOPEZ CONSTRUCTION in HIGHWAY 15 NORTH, PONTOTOC, MS 38863 (NAICS 238160). OSHA activity number 338161029.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABEL LOPEZ CONSTRUCTION
- Site address
- HIGHWAY 15 NORTH
- City
- PONTOTOC
- State
- MS
- ZIP
- 38863
- Mailing
- 945 BALL ROAD, ECRU, MS 38841
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Feb 13, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. (a) East Jobsite - On or about January 07, 2013 three employees were working below a suspended load. The employees were not wearing hard hats exposing them to struck-by hazards.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.451 G04 I
- Issued
- Feb 13, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. (a) Jobsite - On or about January 07, 2013 an employee was using a Brambles scissor lift to install adhesive tape without the end guardrail chains fastened. The employee was exposed to a fall height of 24 feet.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.760 A01
- Issued
- Feb 13, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems. (a) East Jobsite - On or about January 07, 2013 an employee was on the edge of a 1/12 slope roof staging insulation and sheet metal to be installed on the roof without guardrail system, safety net system or personal fall arrest system. Employee was exposed to a fall height of 17 feet 06 inches.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B01
- Issued
- Feb 13, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. (a) East Jobsite - On or about January 07, 2013 an extension ladder being used by employees was not extended at least 3 feet above the landing of the 1/12 pitch roof edge. The roof edge was 17 feet 06 inches above ground.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.1412 F01
- Issued
- Feb 13, 2013
- Abate by
- Apr 2, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1412(f)(1): At least every 12 months the equipment must be inspected by a qualified person in accordance with paragraph (d) of this section (each shift) except that the corrective action set forth in paragraphs (f)(4), (f)(5), and (f)(6) of this section must apply in place of the corrective action required by paragraphs (d)(2) and (d)(3) of this section. (a) East Jobsite - On or about January 07, 2013 the 1988 Ford 370-4V Boom Truck crane being used to lift insulation and sheet metal roofing has not been inspected by a qualifed person. The company had no documentation of any past inspections.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.1412 F02 XVII
- Issued
- Feb 13, 2013
- Abate by
- Apr 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1412(f)(2)(xvii): Warning labels and decals originally supplied with the equipment by the manufacturer or otherwise required under this standard: Missing or unreadable. (a) East Jobsite - On or about January 07, 2013 a 1988 Ford 370-4V boom yruck crane was being used to lift insulation and sheet metal roofing. The truck crane had missing labels and the capacity label was not readable.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1417 C01
- Issued
- Feb 13, 2013
- Abate by
- Apr 2, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, must be readily available in the cab at all times for use by the operator. (a) East Jobsite - On or about January 07, 2013 the 1988 Ford 370-4V boom truck crane was being used to lift insulation and sheet metal roofing did not have information regarding the operation of the crane.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
More inspections in this industry (NAICS 238160)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338161029.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.