Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SKYBOX PACKAGING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SKYBOX PACKAGING, LLC in 1275 JACK POLLOCK PKWY., MANSFIELD, OH 44905 (NAICS 322211). OSHA activity number 338167026.

Watch Skybox Packaging, LLC — free Get an email when a new federal OSHA severe-injury report for Skybox Packaging, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1275 JACK POLLOCK PKWY.
City
MANSFIELD
State
OH
ZIP
44905
Mailing
1275 JACK POLLOCK PKWY., MANSFIELD, OH 44905
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
70
Ownership type
A

13 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a) Skybox Packaging, LLC - Mansfield, Ohio:  On or about January 9, 2013, the cardboard dust accumulation on overhead ductwork, equipment, and steel wall supports exposed employees to fire hazards.  The employer did not assure the areas around the dust collection system were cleaned promptly and to its entirety.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.23 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, employees were exposed to a fall hazard of approximately five feet when accessing a platform on the #128 Hooper press to change and/or check ink levels.  Employees were not protected by a standard guardrail.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.133 A03

Serious Gravity 1 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
29 CFR 1910.133(a)(3): The employer did not assure that each affected employee who wears prescription lenses while engaged in operations that involve eye hazards wears eye protection that incorporates the prescription in its design, or wears eye protection that can be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 9, 2013, the employer did not assure that employees who operated or cleaned machinery in production areas wore eye protection over their prescription glasses.  Employees were exposed to eye injury from flying particles created during production and also by using compressed air to clean equipment.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.147 C07 I

Serious Gravity 5 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, the employer did not assure that employees who service folding, cutting, and gluing machines such as, but not limited to, numbers 128, 132, 142, 143, and 152 were adequately trained in the skills required for the safe application, usage, and removal of energy controls.  Employees that perform tasks such as set-up and cleaning were not trained to lockout the machine to protect against unexpected start-up.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.147 D04 I

Serious Gravity 5 5 instances 40 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, the employer did not assure lockout devices were affixed to the energy isolating device(s) of the #128 Hooper machine before operators performed set-up activities.  A potential for unexpected startup of the press areas existed when employees set up the slot and printing sections of the press.      b) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, the employer did not assure lockout devices were affixed to the energy isolating device(s) of the #132 Ward machine before operators performed set-up activities.  A potential for unexpected startup of the press areas existed when employees set up the slot and printing sections of the press.    c) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, the employer did not assure lockout devices were affixed to the energy isolating device(s) of the #142 S&S Flexo machine before operators perform maintenance activities such as machine set-up and/or cleaning. A potential for unexpected startup of the press areas existed when employees set up the slot and printing sections of the press and cleaning the machine at the end of each shift.    d) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, the employer did not assure lockout devices were affixed to the energy isolating device(s) of the #143 Lian Tiee flexo machine before operators perform maintenance activities such as machine set-up, unjamming, and/or cleaning. A potential for unexpected startup of the press areas existed when employees set up the knives, printing dies, and performing daily machine cleaning activities.     e) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, the employer did not assure lockout devices were affixed to the energy isolating device(s) of the #152 Bobst machine before operators perform maintenance activities such as machine set-up and/or cleaning.  A potential for unexpected startup of the press areas existed when employees set-up and performed cleaning operations.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.178 E02

Serious Gravity 1 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
29 CFR 1910.178(e)(2): Fork trucks, where the load presents a hazard, were not equipped with vertical load backrest extensions.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, the employer did not assure that the Mitsubishi forklift (s/n AF82F20700) used in the storage and shipping areas was equipped with a vertical load backrest extension.  Employees were exposed to loose loads that may roll or shift when the forks are extended above the mast.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.212 A01

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 15, 2013, the employer did not assure that the compensators, or the "open/close" motors, located on the side of the #128 Hooper press were guarded to protect against rotating part hazards.    b) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 9, 2013, the employer did not assure that the rotating shafts, projecting from the side of the #142 S&S Flexo machine, were guarded to protect against rotating part hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about January 9, 2013, the employer did not assure that employees were protected from rotating parts located in the folding area of the #142 S&S Flexo machine.  Employees were exposed to the rotating parts when in the area making adjustments to nearby equipment.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about December 15, 2012, the employer did not assure maintenance personnel were provided with training on electric shock, arc flash hazards, and protective equipment for the body, face, and head to protect against electrical hazards while working on or near potentially energized conductors.  Maintenance workers were exposed to 480 volt electrical hazards while performing electrical tests on machine #143 and the die cutter.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.333 A

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about December 15, 2012, the employer did not develop and implement electrical safety related work practices which cover employees exposed to potentially live conductors while performing electrical work.  Maintenance personnel that conducted troubleshooting and/or performing electrical tests on machine #143 and the die cutter were exposed to 480 volt electrical hazards in that safe work practices were not employed to prevent electrical shock or other injuries.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about December 15, 2012, the employer did not assure a maintenance worker, verifying the absence of electrical energy in an electrical distribution panel for machine #143 was provided with and used electrical protective equipment for the hands and body.  The employee was exposed to 480 volts while performing the electrical test.    b) Skybox Packaging, LLC - Mansfield, Ohio: On or about December 21, 2012, the employer did not assure a maintenance worker, troubleshooting electrical energy for a die cutter machine was provided with and used electrical equipment for the hands and body.  The employee was exposed to 480 volts while troubleshooting live parts.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.335 A01 IV

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(1)(iv): Employees did not wear nonconductive head protection wherever there is a danger of head injury from electric shock or burns due to contact with exposed energized parts.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about December 15, 2012, the employer did not assure a maintenance worker, verifying the absence of electrical energy in an electrical distribution panel for machine #143 was provided with and used electrical protective equipment for head.  The employee was exposed to 480 volts while performing the electrical test without a nonconductive hard hat.    b) Skybox Packaging, LLC - Mansfield, Ohio: On or about December 21, 2012, the employer did not assure a maintenance worker, troubleshooting electrical energy for the die cutter for machine #132 was provided with and used electrical equipment for the head.  The employee was exposed to 440 volts while troubleshooting live parts without a nonconductive hard hat.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 V

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(1)(v): Employees did not wear protective equipment for the eyes or face wherever there is danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion.    a) Skybox Packaging, LLC - Mansfield, Ohio: On or about December 15, 2012, the employer did not assure a maintenance worker, verifying the absence of electrical energy in an electrical distribution panel for machine #143 was provided with and used electrical protective equipment for the eyes and face.  The employee was exposed to 480 volts while performing the electrical test.    b) Skybox Packaging, LLC - Mansfield, Ohio: On or about December 21, 2012, the employer did not assure a maintenance worker, troubleshooting electrical energy for the die cutter for machine #132 was provided with and used electrical equipment for the eyes and face.  The employee was exposed to 440 volts while troubleshooting live parts.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338167026.