Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUN VALLEY MARBLE, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SUN VALLEY MARBLE, INC. in 15 N. ALLUMBAUGH, BOISE, ID 83704 (NAICS 423320). OSHA activity number 338185424.

Watch SUN Valley Marble, INC. — free Get an email when a new federal OSHA severe-injury report for SUN Valley Marble, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15 N. ALLUMBAUGH
City
BOISE
State
ID
ZIP
83704
Mailing
15 N. ALLUMBAUGH, BOISE, ID 83704
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
8
Ownership type
A

7 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1910.212(a)(3)(ii):  Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     (a)  Production area, on or about January 9, 2013, and at times prior thereto, employees were exposed to an unguarded table saw blade while cutting cultured marble and solid surface materials.  Push sticks were used to avoid contact with the unguarded blade.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.106 E02 IV C

Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced

Hazardous substances 2280

29 CFR 1910.106(e)(2)(iv)(c):   Category 1 flammable liquids, with a flashpoint below 100 degrees F (37.8 C), were used where there were sources of ignition within the possible path of vapor travel.    (a)  Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable with a flashpoint of 88 degrees F, in the same area with unapproved electrical junction box wiring.    (b)  Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable with a flashpoint of 88 degrees F, in the same area with unapproved electrical switch for the Rich-Air, air purification system.    (c)  Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable with a flashpoint of 88 degrees F, in the same area with unapproved electrical wall fan wiring.      Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.106 E07 I B

Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2280

29 CFR 1910.106(e)(7)(i)(b):   Locations where flammable vapor-air mixtures may exist under normal operations were not classified Class I, Division 1 according to the requirements of subpart S of this part, and were within 5 feet in all directions from all points of vapor liberation.      (a)  Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable, in the same area with unapproved electrical junction box wiring.    (b)  Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable, in the same area with unapproved electrical switch for the Rich-Air, air purification system.    (c)  Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable, in the same area with unapproved electrical wall fan wiring.      Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E05 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(e)(5)(i):  Portable fire extinguishment and control equipment shall be provided in such quantities and types as are needed for the special hazards of operation and storage.    (a)  Manufacturing mixing area,  on or about January 9, 2013, and at times prior thereto, did not have a fire extinguisher near the mixers where employees mixed resin containing styrene (a Class I flammable liquid).    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 E

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(e):  A side-hinged exit door was not used.    (a)  Production area, North wall, on or about January 9, 2013, and at times prior thereto, overhead door was the primary means of exit.    (b)  Middle of facility, wall between Manufacturing and Production, on or about January 9, 2013, and at times prior thereto, an overhead door was designated as an exit.      Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.36 G02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(g)(2):   Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.    (a)  West exit door, on or about January 9, 2013, and at times prior thereto, drags on concrete pad outside of the door, not allowing it to open all the way.  Door opens approximately 20 inches.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a)   Production area, on or about January 9, 2013, and at times prior thereto, where access to the west wall electrical panel was blocked by storage of plywood and other work materials.      Note:  Abatement certification is NOT required.  Abatement was completed during the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338185424.