BOISE, ID —
OSHA Inspection: SUN VALLEY MARBLE, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SUN VALLEY MARBLE, INC. in 15 N. ALLUMBAUGH, BOISE, ID 83704 (NAICS 423320). OSHA activity number 338185424.
Where did this inspection happen?
- Establishment
- SUN VALLEY MARBLE, INC.
- Site address
- 15 N. ALLUMBAUGH
- City
- BOISE
- State
- ID
- ZIP
- 83704
- Mailing
- 15 N. ALLUMBAUGH, BOISE, ID 83704
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423320
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Production area, on or about January 9, 2013, and at times prior thereto, employees were exposed to an unguarded table saw blade while cutting cultured marble and solid surface materials. Push sticks were used to avoid contact with the unguarded blade. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.106 E02 IV C
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
2280
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(c): Category 1 flammable liquids, with a flashpoint below 100 degrees F (37.8 C), were used where there were sources of ignition within the possible path of vapor travel. (a) Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable with a flashpoint of 88 degrees F, in the same area with unapproved electrical junction box wiring. (b) Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable with a flashpoint of 88 degrees F, in the same area with unapproved electrical switch for the Rich-Air, air purification system. (c) Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable with a flashpoint of 88 degrees F, in the same area with unapproved electrical wall fan wiring. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.106 E07 I B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
2280
General-duty citation text
29 CFR 1910.106(e)(7)(i)(b): Locations where flammable vapor-air mixtures may exist under normal operations were not classified Class I, Division 1 according to the requirements of subpart S of this part, and were within 5 feet in all directions from all points of vapor liberation. (a) Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable, in the same area with unapproved electrical junction box wiring. (b) Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable, in the same area with unapproved electrical switch for the Rich-Air, air purification system. (c) Marble manufacturing, West wall of mixing area; on or about January 9, 2013, and at times prior thereto, employees were mixing several gallons of resin containing styrene, a Class I flammable, in the same area with unapproved electrical wall fan wiring. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(e)(5)(i): Portable fire extinguishment and control equipment shall be provided in such quantities and types as are needed for the special hazards of operation and storage. (a) Manufacturing mixing area, on or about January 9, 2013, and at times prior thereto, did not have a fire extinguisher near the mixers where employees mixed resin containing styrene (a Class I flammable liquid). Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.36 E
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.36(e): A side-hinged exit door was not used. (a) Production area, North wall, on or about January 9, 2013, and at times prior thereto, overhead door was the primary means of exit. (b) Middle of facility, wall between Manufacturing and Production, on or about January 9, 2013, and at times prior thereto, an overhead door was designated as an exit. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.36 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. (a) West exit door, on or about January 9, 2013, and at times prior thereto, drags on concrete pad outside of the door, not allowing it to open all the way. Door opens approximately 20 inches. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Production area, on or about January 9, 2013, and at times prior thereto, where access to the west wall electrical panel was blocked by storage of plywood and other work materials. Note: Abatement certification is NOT required. Abatement was completed during the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423320)
GIBSONIA, PA—2026-06-30
FORM TECH CONCRETE FORMS
BLOOMSDALE, MO—2026-06-25
RICHARDS BRICK COMPANY
SAN JOSE, CA—2026-06-24
STONEVILLE USA, INC.
GRANDVIEW, WA—2026-06-18
WA317991864 - WESTERN MATERIALS INC
MACOMB, MI—2026-06-16
GRANITE & MARBLE DEPOT, INC
More inspections in ID
GOODING, ID—2026-07-10
DAHLGREN INDUSTRIAL INC.
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
BOISE, ID—2026-07-09
MARK GUHO CONSTRUCTION COMPANY
Source