Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUILD RIGHT SERVICES CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BUILD RIGHT SERVICES CORPORATION in 4 GREAT PLAIN AVENUE, WELLESLEY, MA 02482 (NAICS 236115). OSHA activity number 338191216.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Build Right Services Corporation — free Get an email when a new federal OSHA severe-injury report for Build Right Services Corporation is published. One employer, no account, unsubscribe in one click.
Site address
4 GREAT PLAIN AVENUE
City
WELLESLEY
State
MA
ZIP
02482
Mailing
26 B VICTOR ROAD EXT, FRAMINGHAM, MA 01702
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 28, 2013
Abate by
Mar 6, 2013
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)    Jobsite:  second floor    The scaffold used to access the garage gable was not fully planked.
Recent events (1)
  • — Z (S) $2200

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 28, 2013
Abate by
Mar 6, 2013
Penalty
Initial $2,640 · Current $2,640
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.      Jobsite:  Second floor    Scaffolds were accessed from access points that were more than 2 feet below the scaffold.
Recent events (1)
  • — Z (S) $2640

1926.454 A

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 28, 2013
Abate by
Mar 26, 2013
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.454(a):     The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.    Jobsite:    Employees were not adequately trained in scaffold safety.
Recent events (1)
  • — Z (S) $3080

1926.503 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 28, 2013
Abate by
Mar 26, 2013
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.503(a)(1):     The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    Jobsite:    Employees were not adequately trained in fall protection.
Recent events (1)
  • — Z (S) $3080

1926.501 B13

Repeat Gravity 10 1 instance 4 exposed
Issued
Feb 28, 2013
Penalty
Initial $6,160 · Current $6,160
29 CFR 1926.501(b)(13):     Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    Jobsite:    Employees were exposed to fall hazards of up to approximately 26 feet while working on the second floor, the attic floor, and the gabled garage wall.    Instances:    a)  Unguarded window openings on second floor,    b)  Unprotected floor edges on second floor,    c)  Unprotected floor edges in the attic, and    d)  Employee working on garage gabled wall without being tied off.    BUILD RIGHT SERVICES CORPORATION WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.501 (b)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 316106517, CITATION NUMBER 1, ITEM 4, ISSUED ON JANUARY 25, 2012 WITH A FINAL ORDER DATE OF FEBRUARY 15, 2012.
Recent events (1)
  • — Z (R) $6160

View Build Right Services Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338191216.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.