Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GIOVANNI BECERRA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GIOVANNI BECERRA in 2500 UNIVERSITY PLACE, NW, WASHINGTON, DC 20009 (NAICS 238220). OSHA activity number 338200017.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Giovanni Becerra — free Get an email when a new federal OSHA severe-injury report for Giovanni Becerra is published. One employer, no account, unsubscribe in one click.
Establishment
GIOVANNI BECERRA
Site address
2500 UNIVERSITY PLACE, NW
City
WASHINGTON
State
DC
ZIP
20009
Mailing
7532 AMBERGATE PLACE APT #3, MC LEAN, VA 22102
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
A

8 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Abate by
Feb 14, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    a) 2500 University Place NW Job Site - An employee was not provided adequate hazard recognition training as noted where the employee was using a Makita portable electric hammer drill, model number HM1810, to break up an existing concrete slab and not using a ground fault circuit interrupter or an assured equipment grounding conductor program. Also the plug cap for the Makita hammer drill was for a three wire type service and the cord for the hammer drill was a two wire service, the temporary electric receptacle was missing a cover plate exposing live electrical parts, and the outlet was not mounted and hanging by its service conductors, 120 volt, 15 amp service, on or about 01/08/2013.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.403 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted:    a) 2500 University Place NW Basement Apartment Area- A laborer was using a duplex electrical receptacle to supply power to a Makita portable electric hammer drill, model #HM1810, and the receptacle was hanging by the service conductors, 120 volt, 15 amp service, on or about 01/08/2013.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 I02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:    a) 2500 University Place NW Basement Apartment Area - A laborer was using a temporary duplex electrical receptacle to provide power to a Makita portable electric hammer drill, model number HM1810, and the cover plate was missing exposing employees to live electrical parts, 120 volt, 15 amp service, on or about 01/08/2013.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 D

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front:    a) 2500 University Place Basement Apartment Area - A laborer was using an extension cord to supply power to a Makita portable electric hammer drill, model number HM1810, and the temporary duplex receptacle was within 18 inches of a temporary service panel that was missing the cover, exposing the laborer to live electrical parts, on or about 01/08/2013.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Abate by
Feb 14, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    a) 2500 University Place NW Basement Apartment Area - A laborer was using a temporary duplex electrical receptacle to provide power to a Makita portable electric hammer drill, model number HM1810, and a ground fault circuit interrupter or an assured equipment grounding conductor program was not provided, 120 volt, 15 amp service, on or about 01/08/2013.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) 2500 University Place NW Exterior West Side of Building - The company owner and a worker were  exposed to a fall hazard while walking on a 2 by 12" wood board while exiting the building. One end of the board was resting on the first floor level and the other end on a concrete retaining wall, 12'3" above the concrete basement, on or about 01/08/2013.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.1052 C01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    a) 2500 University Place NW Exterior West Side of Building - The owner and a laborer were observed using a stairway to access the lower level apartment that was 57 inches wide, with 18 risers, with a total height of 12 feet, 3 inches and a handrail was not provided.      No abatement certification or documentation required.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.403 B02

Other-than-serious 1 instance 2 exposed
Issued
Feb 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) 2500 University Place NW Basement Apartment Area - A laborer was using a double insulated Makita portable electric hammer drill, model number HM1810, and the plug cap was of the three wire variety, on or 01/08/2013.     No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338200017.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.