WASHINGTON, DC —
OSHA Inspection: GIOVANNI BECERRA
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GIOVANNI BECERRA in 2500 UNIVERSITY PLACE, NW, WASHINGTON, DC 20009 (NAICS 238220). OSHA activity number 338200017.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GIOVANNI BECERRA
- Site address
- 2500 UNIVERSITY PLACE, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 7532 AMBERGATE PLACE APT #3, MC LEAN, VA 22102
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 2
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.21 B02
- Issued
- Feb 8, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) 2500 University Place NW Job Site - An employee was not provided adequate hazard recognition training as noted where the employee was using a Makita portable electric hammer drill, model number HM1810, to break up an existing concrete slab and not using a ground fault circuit interrupter or an assured equipment grounding conductor program. Also the plug cap for the Makita hammer drill was for a three wire type service and the cord for the hammer drill was a two wire service, the temporary electric receptacle was missing a cover plate exposing live electrical parts, and the outlet was not mounted and hanging by its service conductors, 120 volt, 15 amp service, on or about 01/08/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.403 D01
- Issued
- Feb 8, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted: a) 2500 University Place NW Basement Apartment Area- A laborer was using a duplex electrical receptacle to supply power to a Makita portable electric hammer drill, model #HM1810, and the receptacle was hanging by the service conductors, 120 volt, 15 amp service, on or about 01/08/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 I02 I
- Issued
- Feb 8, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) 2500 University Place NW Basement Apartment Area - A laborer was using a temporary duplex electrical receptacle to provide power to a Makita portable electric hammer drill, model number HM1810, and the cover plate was missing exposing employees to live electrical parts, 120 volt, 15 amp service, on or about 01/08/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 D
- Issued
- Feb 8, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front: a) 2500 University Place Basement Apartment Area - A laborer was using an extension cord to supply power to a Makita portable electric hammer drill, model number HM1810, and the temporary duplex receptacle was within 18 inches of a temporary service panel that was missing the cover, exposing the laborer to live electrical parts, on or about 01/08/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 B01 I
- Issued
- Feb 8, 2013
- Abate by
- Feb 14, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) 2500 University Place NW Basement Apartment Area - A laborer was using a temporary duplex electrical receptacle to provide power to a Makita portable electric hammer drill, model number HM1810, and a ground fault circuit interrupter or an assured equipment grounding conductor program was not provided, 120 volt, 15 amp service, on or about 01/08/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.501 B13
- Issued
- Feb 8, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 2500 University Place NW Exterior West Side of Building - The company owner and a worker were exposed to a fall hazard while walking on a 2 by 12" wood board while exiting the building. One end of the board was resting on the first floor level and the other end on a concrete retaining wall, 12'3" above the concrete basement, on or about 01/08/2013. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1052 C01 I
- Issued
- Feb 8, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) 2500 University Place NW Exterior West Side of Building - The owner and a laborer were observed using a stairway to access the lower level apartment that was 57 inches wide, with 18 risers, with a total height of 12 feet, 3 inches and a handrail was not provided. No abatement certification or documentation required.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.403 B02
- Issued
- Feb 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) 2500 University Place NW Basement Apartment Area - A laborer was using a double insulated Makita portable electric hammer drill, model number HM1810, and the plug cap was of the three wire variety, on or 01/08/2013. No abatement certification or documentation required.
Recent events (2)