ELMSFORD, NY —
OSHA Inspection: U.S. SEAMLESS INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of U.S. SEAMLESS INC. in 25 VALLEY AVE., ELMSFORD, NY 10523 (NAICS 238170). OSHA activity number 338216625.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. SEAMLESS INC.
- Site address
- 25 VALLEY AVE.
- City
- ELMSFORD
- State
- NY
- ZIP
- 10523
- Mailing
- 340 1ST STREET, NEWBURGH, NY 12550
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.416 E01
- Issued
- Feb 19, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used. a) Job Site, 25 Valley Ave, Elmsford, NY: A 1 1/2" section of the outer insulation jacket on the 100 ft. long extension cord(black/green) that was connected to an indentified screw gun was worn out, on or about 1/10/2013.
Recent events (1)
- — Z (S) $1200
1926.501 B13
- Issued
- Feb 19, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. A) Job Site, 25 Valley Ave, Elmsford, NY: One (1) employee working on the residential roof removing a gutte,r was not protected from falling approximately 20' feet below; on or about 1/10/13.
Recent events (1)
- — Z (S) $2800
More inspections at U.S. Seamless INC.
View U.S. Seamless INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338216625.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.