FORT PAYNE, AL —
OSHA Inspection: HEIL ENVIRONMENTAL
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HEIL ENVIRONMENTAL in 106 45TH STREET NE, FORT PAYNE, AL 35967 (NAICS 336211). OSHA activity number 338226616.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEIL ENVIRONMENTAL
- Site address
- 106 45TH STREET NE
- City
- FORT PAYNE
- State
- AL
- ZIP
- 35967
- Mailing
- 106 45TH STREET NE, FORT PAYNE, AL 35967
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336211
- Employees
- 450
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.176 A
- Issued
- Mar 18, 2013
- Abate by
- Apr 20, 2013
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.176(a): Permanent aisles and passageways were not appropriately marked: (a) On or about January 11, 2013 - Parts Central Warehouse, aisles and passageways where forklifts traveled were not marked.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.252 B02 III
- Issued
- Mar 18, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: (a) On or about January 9, 2013 - Manufacturing Building, Welding Lines, noncombustible screens were not provided to protect other employees or persons in the DPF line area from welding rays. (b) On or about January 11, 2013 - Parts Central, CCI Welding Area, noncombustible screens were not provided to protect other employees and persons from welding rays.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
More inspections in this industry (NAICS 336211)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338226616.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.