MERRILL, WI —
OSHA Inspection: MERRILL HOLDING AND TRANSPORT COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MERRILL HOLDING AND TRANSPORT COMPANY in 1000 STATE ST., MERRILL, WI 54452 (NAICS 484121). OSHA activity number 338241227.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MERRILL HOLDING AND TRANSPORT COMPANY
- Site address
- 1000 STATE ST.
- City
- MERRILL
- State
- WI
- ZIP
- 54452
- Mailing
- 1000 STATE ST., MERRILL, WI 54452
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L01 II
- Issued
- Feb 20, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial vehicle: a) On or about January 14, 2013 the company had not ensured that each employee(s) operating a forklift and/or other material handling equipment had completed the required training under paragraph (l) of this section. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1910.178 L06
- Issued
- Feb 20, 2013
- Abate by
- Mar 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) On or about January 14, 2013 the employer did not provide documentation certifying that each operator had been trained and evaluated as required by this section. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Feb 20, 2013
- Abate by
- Mar 4, 2013
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) On or about January 14, 2013 the pull box underneath electrical disconnect on the north wall in the maintenance area was not covered, exposing live electrical wiring. b) On or about January 14, 2013 the junction box fixed next to the personnel door on the east wall of the maintenance area was not covered, exposing live electrical wiring Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1910.23 C01
- Issued
- Feb 20, 2013
- Abate by
- Mar 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toe-boards: a) On or about January 14, 2013 a four (4) ft. section in the concrete barriers placed along the north end of the storage shed was not covered to provide sufficient guarding from the fall hazard behind it. The four (4) ft. section was 24 inches high. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Feb 20, 2013
- Abate by
- Mar 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about January 14, 2013 miscellaneous materials were stored on and in the pull tray on the north wall of the maintenance area. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Merrill Holding and Transport Company
View Merrill Holding and Transport Company's full OSHA safety record →
More inspections in this industry (NAICS 484121)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338241227.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.