Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KINDRED HEALTHCARE DBA CHESTNUT TERRACE NURSING AND REHABILITATION CENTER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KINDRED HEALTHCARE DBA CHESTNUT TERRACE NURSING AND REHABILITATION CENTER in 100 WAMPANOAG TRAIL, EAST PROVIDENCE, RI 02914 (NAICS 623110). OSHA activity number 338259419.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kindred Healthcare DBA Chestnut Terrace Nursing and Rehabilitation Center — free Get an email when a new federal OSHA severe-injury report for Kindred Healthcare DBA Chestnut Terrace Nursing and Rehabilitation Center is published. One employer, no account, unsubscribe in one click.
Site address
100 WAMPANOAG TRAIL
City
EAST PROVIDENCE
State
RI
ZIP
02914
Mailing
100 WAMPANOAG TRAIL, EAST PROVIDENCE, RI 02914
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
65
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 12, 2013
Abate by
Jan 7, 2014
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Throughout the establishment:  On or about 1/16/2013, the employer did not develop energy control procedures for the servicing and maintenance of equipment, such as but not limited to, kitchen equipment, hoyer lifts and other equipment onsite.
Recent events (1)
  • — Z (S) $2975

1910.333 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 12, 2013
Abate by
Jan 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(i): The employer did not make a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized representatives:   a) Throughout the Establishment: On or about 1/16/2013, the employer did not develop written energy control procedures for the servicing and maintenance of equipment, such as but not limited to, the changing of electric starters, electric beds, and other electrical equipment onsite.
Recent events (1)
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 12, 2013
Abate by
Aug 26, 2013
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Establishment: On or about 1/15/2013, the employer had not conducted the periodic inspection of their Lockout/Tagout program.  "Abatement Documentation Required"
Recent events (1)
  • — Z (S) $2975

1910.332 B03

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 12, 2013
Penalty
Initial $2,529 · Current $2,529
29 CFR 1910.332(b)(3):  Qualified persons (i.e. those permitted to work on or near exposed energized parts) were not trained in and familiar with all of the requirement in 29 CFR 1910.332(b)(3) through 29 CFR 1910.332(b)(3)(iii):   a) Establishment: On or about 1/16/2012, employees were permitted to perform testing to assure that the equipment to be worked on is de-energized, using a fluke meter, and had not been provided with training required by 29 CFR 1910.332(b)(3) through 29 CFR 1910.332(b)(3)(iii).
Recent events (1)
  • — Z (S) $2529

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 12, 2013
Abate by
Aug 26, 2013
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  a) Establishment:  On or about 1/16/2013, an employee was using a fluke meter to check that various electrical equipment to be worked on was not energized and had not been provided with electrical protective equipment, such as but not limited to, gloves, clothing for arc flash protection, faceshield and safety glasses.   Note: Personal protective equipment requirements are contained in subpart I of this part.  "Abatement Documentation is Required"
Recent events (1)
  • — Z (S) $2975

View Kindred Healthcare DBA Chestnut Terrace Nursing and Rehabilitation Center's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338259419.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.