MOUNTAIN HOME, ID —
OSHA Inspection: B TRANSFER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of B TRANSFER, INC. in 890 WEST 6TH SOUTH, MOUNTAIN HOME, ID 83647 (NAICS 484210). OSHA activity number 338259815.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- B TRANSFER, INC.
- Site address
- 890 WEST 6TH SOUTH
- City
- MOUNTAIN HOME
- State
- ID
- ZIP
- 83647
- Mailing
- 890 WEST 6TH SOUTH, MOUNTAIN HOME, ID 83647
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484210
- Employees
- 23
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 4, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees used forklift to elevate personnel: (a) Warehouse 1: on 01/07/13 and at times prior thereto, workers accessed long-term storage areas at least 10 feet 3 inches high while being supported by a shop-made flat pallet without guardrails, mid-rails and toe-boards which was not secured to the H35XL Hyster forklift. NOTE: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.23 C01
- Issued
- Mar 4, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: (a) Warehouse 1 mezzanine storage areas: On 1/7/13 and at times prior thereto, workers were able to access a 9' mezzanine that did not have standard railings or another method of fall protection. Note 1: Railings shall have toeboards when beneath the open sides, persons can pass, there is moving machinery, or there is equipment with which falling materials could create a hazard. Note 2: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.27 C04
- Issued
- Mar 4, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.27(c)(4): The employer did not install fixed ladders with at least 7 inches of clearance from the centerline of the rung to the nearest permanent object in the back of the ladder. (a) Warehouse 1: on 1/7/12 and at times prior thereto, a fixed ladder constructed of 2X4 lumber does not have adequate clearance from the wall to the centerline of the rung. Note 1: Abatement certification IS required for this item. Note 2: Figure D-3 of 29 CFR 1910.27 provides guidance for constructing fixed ladders.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.27 D03
- Issued
- Mar 4, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.27(d)(3): The employer did not ensure that the side rails of a through ladder extended 3 1/2 feet above parapets and landings with rungs omitted from the extension and having between 18 and 24 inches clearance between the rails. (a) Warehouse 1: On 1/7/13 and at times prior thereto, the left side ladder extension was missing from a fixed wooden ladder leading to the mezzanine. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Mar 4, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Warehouse 2 panel: On 1/7/13 and at times prior thereto, a circuit breaker was not installed and the opening was not covered. NOTE: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at B Transfer, INC.
View B Transfer, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 484210)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338259815.