MIAMI, FL —
OSHA Inspection: MNCP INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MNCP INC. in 4032 SW 137TH AVE, MIAMI, FL 33175 (NAICS 236220). OSHA activity number 338268816.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MNCP INC.
- Site address
- 4032 SW 137TH AVE
- City
- MIAMI
- State
- FL
- ZIP
- 33175
- Mailing
- 16988 SW 141 CT, MIAMI, FL 33177
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Feb 13, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 1/14/13, at the above referenced jobsite, two employees were observed working from a scaffold that was not fully planked at the working level.
Recent events (1)
- — Z (S) $2000
1926.451 E01
- Issued
- Feb 13, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On or about 1/14/13, at the above referenced jobsite, two employees were observed working from a scaffold without an adequate means of access.
Recent events (1)
- — Z (S) $2000
1910.1200 E01
- Issued
- Feb 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about 1/14/13, at the above referenced jobsite, the employer did not develop a written hazard communication program for employees using hazardous products such as the Titan stucco cement.
Recent events (1)
- — Z (O) $0
1910.1200 G01
- Issued
- Feb 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: On or about 1/14/13, at above referenced jobsite, the employer did not maintain material safety data sheets for hazardous products used at the workplace.
Recent events (1)
- — Z (O) $0
More inspections at Mncp INC.
View Mncp INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338268816.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.