Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R.P. FEDDER CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R.P. FEDDER CORPORATION in 740 DRIVING PARK AVENUE, ROCHESTER, NY 14613 (NAICS 333411). OSHA activity number 338300015.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.P. Fedder Corporation — free Get an email when a new federal OSHA severe-injury report for R.P. Fedder Corporation is published. One employer, no account, unsubscribe in one click.
Site address
740 DRIVING PARK AVENUE
City
ROCHESTER
State
NY
ZIP
14613
Mailing
740 DRIVING PARK AVENUE, ROCHESTER, NY 14613
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333411
Employees
25
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 3 instances 4 exposed
Issued
Jan 23, 2013
Abate by
Feb 27, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) On or about 1/16/13 in the shop area; employees are performing service and maintenance ( installing and removing dies, product change-overs, set ups, threading mylar film through the die area ) on the Preco machine without using the ram stop blocks and locking out the energy isolation device.      b) On or about 1/16/13 in the shop area; employees are performing service and maintenance ( installing and removing dies, placing make ready sheets ) on the Contech machine without documenting and utilizing a procedure for locking out the energy isolation device.      c) On or about 1/16/13 in the Pleater room area; employees are performing service and maintenance ( cleaning the crimpers, performing set up and change overs ) on the mini-pleater machine without documenting and utilizing a procedure for locking out the energy isolation device.      Abatement Certification
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.147 C07 I A

Serious Gravity 5 3 instances 3 exposed
Issued
Jan 23, 2013
Abate by
Feb 27, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.147(c)(7)(i)(A):     Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources and the methods and means necessary for energy isolation.     a) On or about 1/16/13 in the shop area; employees are performing service and maintenance ( installing and removing dies, product change-overs, set ups, threading mylar film through the die area ) on the Preco machine without being trained on the requirements to use the ram stop blocks and lock out the energy isolation device.      b) On or about 1/16/13 in the shop area; employees are performing service and maintenance ( installing and removing dies, placing make ready sheets ) on the Contech machine without being trained on the requirement to lock out the energy isolation device.      c) On or about 1/16/13 in the Pleater room area; employees are performing service and maintenance ( cleaning the crimpers, performing set up and change overs ) on the mini pleater machine without being trained on the requirement to lock out the energy isolation device.      Abatement Certification
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.147 C06 I

Other-than-serious 1 instance 5 exposed
Issued
Jan 23, 2013
Abate by
Feb 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the requirement of this standard were being followed:    a) On or about 1/16/13 throughout the facility; employer requires employees to perform service and maintenance, such as but not limited to, set up, product change over, die changes, cleaning, repairs, and last conducted a periodic inspection of the use of energy control procedures in 2009.      Abatement Certification
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View R.P. Fedder Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338300015.