Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONCRETE PRODUCTS OF THE PALM BEACHES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CONCRETE PRODUCTS OF THE PALM BEACHES INC. in 460 AVENUE S, RIVIERA BEACH, FL 33404 (NAICS 327390). OSHA activity number 338311814.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Concrete Products of the Palm Beaches INC. — free Get an email when a new federal OSHA severe-injury report for Concrete Products of the Palm Beaches INC. is published. One employer, no account, unsubscribe in one click.
Site address
460 AVENUE S
City
RIVIERA BEACH
State
FL
ZIP
33404
Mailing
460 AVENUE S, RIVIERA BEACH, FL 33404
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
27
Ownership type
A

10 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 22, 2013
Abate by
Mar 29, 2013
Penalty
Initial $2,100 · Current $1,150 Reduced
29 CFR 1910.22(a)(1):  All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a.  On or about 1/16/13, at the warehouse area of the above referenced jobsite, employees were exposed to an electrical fire hazard while working in an area where wood dust was accumulated over electrical equipment and wiring.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2100

1910.178 L01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 22, 2013
Abate by
Apr 2, 2013
Penalty
Initial $2,100 · Current $1,150 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a.  On or about 1/16/13, at the manufacturing area of the above referenced jobsite, an employee operated a powered industrial truck without being trained.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2100

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 22, 2013
Abate by
Apr 2, 2013
Penalty
Initial $3,500 · Current $1,950 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:     a.  On or about 1/16/13, at the warehouse area of the above referenced jobsite, an employee was exposed to a caught-by hazard while working with a drill press (i.e. Central Machinery, Item #43389) that lacked a guard on its point of operation.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3500

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 22, 2013
Abate by
Apr 2, 2013
Penalty
Initial $2,100 · Current $1,150 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving    a.  On or about 1/16/13, at the warehouse area of the above referenced jobsite, an employee was exposed to a struck by hazard while working with a drill press (i.e. Central Machinery, Item #43389) that was not anchored.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2100

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 22, 2013
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch:    a.  On or about 1/16/13, at the warehouse area of the above referenced jobsite, an employee was exposed to a struck by hazard while working with a bench grinder (i.e. Porter Cable, Serial #020422) that had its left side work rest placed at 1/2" from the wheel periphery.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 22, 2013
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a.  On or about 1/16/13, at the warehouse area of the above referenced jobsite, an employee was exposed to an electrical hazard while using a microwave oven (i.e. Panasonic) that lacked a continuous path to ground.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1910.22 D01

Other-than-serious 1 instance 3 exposed
Issued
Mar 22, 2013
Abate by
Apr 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1):  On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:    a.  On or about 1/16/13, at the warehouse area of the above referenced jobsite, employees were exposed to a struck by hazard while miscellaneous equipment and materials were stored over the employee's bathrooms area, and load limits were not posted.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02

Other-than-serious 1 instance 1 exposed
Issued
Mar 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a.  On or about 1/16/13, at the warehouse area of the above referenced jobsite, an employee was exposed to an electrical fire hazard while working in an area where an electrical junction box lacked a cover plate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV B

Other-than-serious 1 instance 1 exposed
Issued
Mar 22, 2013
Abate by
Mar 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B):  Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where run through holes in walls, ceilings, or floors:     a.  On or about 1/16/13, at the rebar manufacturing area of the above referenced jobsite, an employee was exposed to a fire hazard while working with a welding machine which had its cord passing through a hole in a wall.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 2 instances 1 exposed
Issued
Mar 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    On or about 1/16/13, at the rebar manufacturing area of the above referenced jobsite:     a. An employee was exposed to an electrical hazard while working with an extension cord that lacked strain relief at the female and male end attachment plugs.      b. An employee was exposed to an electrical hazard while operating a rebar cutting machine by using a pedal that lacked strain relief where the cord entered into the pedal.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Concrete Products of the Palm Beaches INC.'s full OSHA safety record →