COLORADO SPRINGS, CO —
OSHA Inspection: ROOF CRAFTERS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ROOF CRAFTERS in 1901 DEWHIRST DRIVE, COLORADO SPRINGS, CO 80907 (NAICS 236118). OSHA activity number 338312010.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROOF CRAFTERS
- Site address
- 1901 DEWHIRST DRIVE
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80907
- Mailing
- 2215 WESTMORELAND ROAD, COLORADO SPRINGS, CO 80907
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 18, 2013
- Abate by
- Jan 25, 2013
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) On or about January 9, 2013, employees were exposed to fall hazards in excess of 10 feet, while installing a new roof without fall protection. Abatement Note: Abatement certification and documentation is required for this item. (see enclsoed Certification of Corrective Action worksheet).
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1926.1053 B01
- Issued
- Jan 18, 2013
- Abate by
- Jan 25, 2013
- Penalty
- Initial $2,400 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about January 9, 2013, employes were exposed to fall hazards while using an extension ladder that did not extend at least 3 feet above the upper landing surface nor was the ladder secured in place to prevent accidnetial displacement. Abatement Note: Abatement certification is required for this item. (See Certification of Corrective Action worksheet).
Recent events (2)
- — I (S) $1000
- — Z (S) $2400
1926.1053 B06
- Issued
- Jan 18, 2013
- Abate by
- Jan 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladders were used on surfaces that were not stable and level: (a) On or about January 9, 2013, employees were exposed to fall hazards while using an unsecured extension ladder to access the roof area. The ladder was placed on a slope of dirt and the footing of the left side rail was not engaged.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A01 III
- Issued
- Jan 18, 2013
- Abate by
- Jan 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: (a) On or about Janaury 9, 2013, the ladder used by employees to access the roof area was not placed properly to ensure safe access.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Roof Crafters
View Roof Crafters's full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338312010.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.