Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BAYLAND BUILDINGS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BAYLAND BUILDINGS INC in 7460 HWY 42/57, STURGEON BAY, WI 54235 (NAICS 236220). OSHA activity number 338316821.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bayland Buildings INC — free Get an email when a new federal OSHA severe-injury report for Bayland Buildings INC is published. One employer, no account, unsubscribe in one click.
Site address
7460 HWY 42/57
City
STURGEON BAY
State
WI
ZIP
54235
Mailing
PO BOX 13571, GREEN BAY, WI 54307
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
180
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 27, 2013
Abate by
May 15, 2013
Penalty
Initial $6,930 · Current $3,000 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and fall from elevation hazards relating to improperly braced trusses:      a) On 01-15-13, employees who were installing trusses with sixty (60) foot spans for a new addition to an existing commercial building did not install the required temporary lateral, diagonal, and web bracing; employees were exposed to struck by and fall from elevation hazards associated with the improperly braced trusses.    Among other methods, one feasible and acceptable means to correct these hazards is to follow the Building Component Safety Information (BCSI-2008) guidelines for temporary bracing.  This information was available on site.       ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $3000
  • — Z (S) $6930

1926.501 B15

Serious Gravity 10 2 instances 1 exposed
Issued
Mar 27, 2013
Abate by
May 15, 2013
Penalty
Initial $6,930 · Current $3,100 Reduced
29 CFR 1926.501(b)(15):     Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system:    a)  On 01-15-13, an employee who was installing trusses was walking on the wall top plate at a height greater than fifteen and one half (15.5) feet above concrete surface without utilizing fall protection equipment.    b)  On 01-15-13, an employee who was installing trusses was walking on the bottom cord of trusses at a height greater than fifteen and one half (15.5) feet above concrete surface without utilizing fall protection equipment.        ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $3100
  • — Z (S) $6930

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 27, 2013
Penalty
Initial $4,950 · Current $3,100 Reduced
29 CFR 1926.1053(b)(1):     Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:      a) On 01-15-13, an employee who was installing trusses was utilizing a twenty-eight (28) ft. extension ladder to access/egress a wall top plate working surface greater than fifteen and one half (15.5) feet above concrete surface, without any grab rails extending above the upper landing surface.    NO ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $3100
  • — Z (S) $4950

1926.1060 A01 III

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Mar 27, 2013
Abate by
May 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1)(iii):     The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways:      a) On 01-15-13, an employee, who had not received initial company safety training, did not recognize the hazard associated with using a twenty-eight (28) foot extension ladder's top rung as a step to access/egress a wall plate fifteen and one half (15.5) feet above concrete surface.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1425 C03

Other-than-serious 1 instance 4 exposed
Issued
Mar 27, 2013
Abate by
May 15, 2013
Penalty
Initial $6,930 · Current $0 Reduced
29 CFR 1926.1425(c)(3): The materials were not rigged by a qualified rigger:      a) On 01-15-13, an employee, who was not a qualified rigger, was rigging Alpine ITW Building Components Group Inc. sixty (60) foot long trusses to wire rope slings on a crane by using two web slings; each web sling was located on one side of the center point of the truss, looped around the top cord at a web connection at a distance greater than nine (9) feet from the truss center ridge point.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $6930

1926.503 B01

Other-than-serious 1 instance 2 exposed
Issued
Mar 27, 2013
Abate by
May 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1):     The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:    a) Employer did not provide employee fall protection safety training certification on employees who were working at heights greater than 10 feet above concrete surface; the employees were installing trusses.       ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Bayland Buildings INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338316821.