MIAMI GARDENS, FL —
OSHA Inspection: D&D CONSTRUCTION SERVICES, CORP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D&D CONSTRUCTION SERVICES, CORP in 18255 NW 57 AVE, MIAMI GARDENS, FL 33055 (NAICS 238110). OSHA activity number 338329014.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D&D CONSTRUCTION SERVICES, CORP
- Site address
- 18255 NW 57 AVE
- City
- MIAMI GARDENS
- State
- FL
- ZIP
- 33055
- Mailing
- 851 WEST 31 ST, HIALEAH, FL 33012
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Jan 31, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $2,400 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 1-16-13, employees were working on a scaffold that was not fully planked.
Recent events (2)
- — I (S) $2000
- — Z (S) $2400
1926.451 E01
- Issued
- Jan 31, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: On or about 1/16/13, an employee did not have a ladder to access the scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.451 F07
- Issued
- Jan 31, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: On or about 1/16/13, the prefrabricated frame scaffold was erected by employees who were not supervised by a competetent person.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.451 G04
- Issued
- Jan 31, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph. On or about 01-16-13, two employees were working on a scaffold which did not have guardrails.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.452 C02
- Issued
- Jan 31, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about 1-16-13, the prefabricated frame scaffold did not have cross braces.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.501 B01
- Issued
- Jan 31, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $2,400 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about 01-16-13, an employee was walking on a concrete block wall without any type of fall protection.
Recent events (2)
- — I (S) $2000
- — Z (S) $2400
More inspections in this industry (NAICS 238110)
More inspections in FL