PORTLAND, OR —
OSHA Inspection: US FAB
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of US FAB in 5555 N. CHANNEL AVE, PORTLAND, OR 97217 (NAICS 336611). OSHA activity number 338345259.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- US FAB
- Site address
- 5555 N. CHANNEL AVE
- City
- PORTLAND
- State
- OR
- ZIP
- 97217
- Mailing
- 5555 N. CHANNEL AVE, PORTLAND, OR 97217
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 36
- Ownership type
- A
Citations
4 citations on file for this inspection.
1915.56 B02
- Issued
- Feb 1, 2013
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1915.56(b)(2): Welding cable was not free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected. Hull 16: On or about January 9, 2013, and times prior thereto, a welding stinger had a cut to the conductor 64 inches from the electrode holder. This exposed employees to a shock/burn hazard from contacting the conductor while welding.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1915.56 B04
- Issued
- Feb 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.56(b)(4): When welding cable became worn to the extent of exposing bare conductors, the portion exposed was not protected by means of rubber tape, friction tape, or other equivalent insulation. Hull 16: On or about January 9, 2013, and times prior thereto, the Lincoln welding cable had a cut to the conductor. This exposed employees to a possible shock/burn hazard from incidental contact with the conductor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Feb 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury, and the defective or damaged item was not removed from service: (a) Hull 16 bay area: On or about January 9, 2013, and times prior thereto, an extension cord in use was cut to the conductor. This exposed employees to a potential shock hazard from incidental contact with the conductor. (b) Hull 16 bay area: On or about January 9, 2013, and times prior thereto, an extension cord in use was cut, and burned to the conductor. This exposed employees to a potential shock hazard from incidental contact with the conductor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.72 A01
- Issued
- Feb 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.72(a)(1): Ladders with broken or missing Rungs or steps, broken or split side rails, or other faulty or defective construction were used. Hull 16: on or about January 9, 2013, and times prior thereto, a ladder in use had two damaged rungs. This exposed employees to a fall hazard from the bottom rungs of the ladder.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at US FAB
View US FAB's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338345259.