OSHA Inspection: SOUTHEASTERN FUEL TRANSPORT, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTHEASTERN FUEL TRANSPORT, INC. in 1000 SOMMERS BLVD, RICHMOND HILL, GA 31324 (NAICS 484220). OSHA activity number 338350275.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southeastern Fuel Transport, INC. — free Get an email when a new federal OSHA severe-injury report for Southeastern Fuel Transport, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1000 SOMMERS BLVD
City
RICHMOND HILL
State
GA
ZIP
31324
Mailing
1000 SOMMERS BLVD, RICHMOND HILL, GA 31324
Inspection type
Planned (H)
Scope
Records only (C)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484220
Employees
15
Ownership type
A

6 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2013
Abate by
Jun 17, 2013
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.37(b)(2):   Each exit was not clearly visible and marked by a sign reading "Exit":   a) Maintenance Shop Adjacent to Overhead Door- On or about January 18, 2013, there was no exit sign installed above the pedestrian exit door in the maintenance shop next to the overhead door, exposing employees to fire hazards.     b) Maintenance Shop Entrance/Exit to Interior Offices- On or about January 18, 2013, there was no exit sign installed above the door in the maintenance shop that leads to the interior offices, exposing employees to fire hazards.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
  • — Z (S) $2380

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2013
Abate by
Jun 17, 2013
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a) Maintenance Shop - On or about January 18, 2013, the drive pulley on the ACS pump that powered the air compressor was not adequately guarded, exposing employees to in going nip points (caught-in hazards).   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
  • — Z (S) $2975

1910.219 E03 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2013
Abate by
Jun 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):   a) Maintenance Shop - On or about January 18, 2013, the vertical and inclined belt drive on the ACS pump that powered the air compressor was not adequately guarded, exposing employees to in going nip points (caught-in hazards).       ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
May 21, 2013
Abate by
Jun 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):   The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Maintenance Shop - On or about January 18, 2013, the employer did not develop, implement, and/or maintain a written hazard communication program at the workplace, exposing employees to possible skin, eye, and respiratory irritations from chemicals including but not limited to oxygen and acetylene being used for cutting/heating and antifreeze, brake fluid, etc. used to service vehicles.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 1 exposed
Issued
May 21, 2013
Abate by
Jun 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:  a) Maintenance Shop - On or about January 18, 2013, the employer did not have a material safety data sheet for chemicals including but not limited to oxygen and acetylene being used for cutting/heating and antifreeze, brake fluid, etc. used to service vehicles, exposing employees to possible skin, eye, and respiratory irritations.      ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 1 exposed
Issued
May 21, 2013
Abate by
Jun 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1):   Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Maintenance Shop - On or about January 18, 2013, employees were not provided with effective hazardous communication training, exposing employees to possible skin, eye, and respiratory irritations from chemicals including but not limited to oxygen and acetylene being used for cutting/heating and antifreeze, brake fluid, etc. used to service vehicles.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
  • — Z (O) $0