OSHA Inspection: JOHNSON CONTROLS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOHNSON CONTROLS INC. in 1320 GOODYEAR, EL PASO, TX 79936 (NAICS 423120). OSHA activity number 338363237.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Johnson Controls INC. — free Get an email when a new federal OSHA severe-injury report for Johnson Controls INC. is published. One employer, no account, unsubscribe in one click.
Site address
1320 GOODYEAR
City
EL PASO
State
TX
ZIP
79936
Mailing
1320 GOODYEAR, EL PASO, TX 79936
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423120
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.22 B01

Serious Gravity 5 5 instances 30 exposed
Issued
Apr 25, 2013
Abate by
May 7, 2013
Penalty
Initial $6,000 · Current $3,600 Reduced
29 CFR 1910.22(b)(1): Where mechanical handling equipment is used, sufficient safe clearances were not allowed for aisles, through doorways and wherever turns or passage must be made. Aisles and passageways were not kept clear, with no obstruction across or in aisles that could create a hazard.  On or about December 17, 2012, and times prior thereto warehouse aisles, and doorways were not kept clear of obstructions. These conditions exposed employees to powered industrial truck struck-by hazards and fire potential hazards.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $6000

1910.157 C01

Other-than-serious 1 instance 30 exposed
Issued
Apr 25, 2013
Abate by
May 7, 2013
Penalty
Initial $1,000 · Current $600 Reduced
29 CFR 1910.157(c)(1): The employer did not have a portable fire extinguisher readily accessible to employees without subjecting the employees to possible injury.  On or about December 17, 2012, a portable fire extinguisher located in the east wall of the warehouse was obstructed as to prevent access. This condition exposed employees to trip and fall hazards.
Recent events (2)
  • — I (O) $600
  • — Z (O) $1000

1910.333 B02

Other-than-serious 1 instance 1 exposed
Issued
Apr 25, 2013
Abate by
May 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2):  Employees exposed to contact with parts of fixed electric equipment or circuits which have been de-energized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph.   On or about December 17, 2012, a fix electrical equipment such as a step-down transformer and control panel with exposed contact parts (Knock-outs open; wires exposed to abrasion) which have been de-energized, the circuits energizing the parts were not locked and tag-out. These conditions exposed employees to electrical hazards.