EL PASO, TX —
OSHA Inspection: JOHNSON CONTROLS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JOHNSON CONTROLS INC. in 1320 GOODYEAR, EL PASO, TX 79936 (NAICS 423120). OSHA activity number 338363237.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOHNSON CONTROLS INC.
- Site address
- 1320 GOODYEAR
- City
- EL PASO
- State
- TX
- ZIP
- 79936
- Mailing
- 1320 GOODYEAR, EL PASO, TX 79936
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423120
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.22 B01
- Issued
- Apr 25, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $6,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Where mechanical handling equipment is used, sufficient safe clearances were not allowed for aisles, through doorways and wherever turns or passage must be made. Aisles and passageways were not kept clear, with no obstruction across or in aisles that could create a hazard. On or about December 17, 2012, and times prior thereto warehouse aisles, and doorways were not kept clear of obstructions. These conditions exposed employees to powered industrial truck struck-by hazards and fire potential hazards.
Recent events (2)
- — I (S) $3600
- — Z (S) $6000
1910.157 C01
- Issued
- Apr 25, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): The employer did not have a portable fire extinguisher readily accessible to employees without subjecting the employees to possible injury. On or about December 17, 2012, a portable fire extinguisher located in the east wall of the warehouse was obstructed as to prevent access. This condition exposed employees to trip and fall hazards.
Recent events (2)
- — I (O) $600
- — Z (O) $1000
1910.333 B02
- Issued
- Apr 25, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2): Employees exposed to contact with parts of fixed electric equipment or circuits which have been de-energized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph. On or about December 17, 2012, a fix electrical equipment such as a step-down transformer and control panel with exposed contact parts (Knock-outs open; wires exposed to abrasion) which have been de-energized, the circuits energizing the parts were not locked and tag-out. These conditions exposed employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Johnson Controls INC.
View Johnson Controls INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338363237.