WINFIELD, MO —
OSHA Inspection: BROOKS BROTHERS TRAILERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BROOKS BROTHERS TRAILERS, INC. in 2656 E. HWY 47, WINFIELD, MO 63389 (NAICS 336212). OSHA activity number 338364839.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BROOKS BROTHERS TRAILERS, INC.
- Site address
- 2656 E. HWY 47
- City
- WINFIELD
- State
- MO
- ZIP
- 63389
- Mailing
- P.O. BOX 358, WINFIELD, MO 63389
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336212
- Employees
- 42
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.107 C02
- Issued
- Feb 21, 2013
- Abate by
- Nov 12, 2013
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.107(c)(2): Open flame or spark producing equipment was not kept from a spraying area nor within 20 feet, unless separated from by a partition: a. In the paint building, where spray painting of flammable liquids was conducted, non-explosion proof electrical wiring and components, such as, but not limited to, 120 V outlets and switches, and an electric refrigerator, were within 10 feet of parts sprayed. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.107 C06
- Issued
- Feb 21, 2013
- Abate by
- Nov 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined (within 20 ft) were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a. In the paint building, where spray painting of flammable liquids was conducted, non-explosion proof electrical wiring and components, such as, but not limited to, 120 V outlets and switches, and an electric refrigerator, were within 10 feet of parts sprayed. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E02 IV A
- Issued
- Feb 21, 2013
- Abate by
- Nov 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(a): Flammable liquids were not kept in covered contianers when not in use: a. In the paint building, where spray painting of flammable liquids was conducted in spray rooms with non-explosion proof electrical wiring and components, such as, but not limited to, 120 V outlets and switches, and an electric refrigerator, containers of small amounts of flammable liquid were left to evaporate; an explosion hazard existed because of the contribution of a flammable atmosphere from the evaporation being ignited by the electrical spark producing equipment. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H
- Issued
- Feb 21, 2013
- Abate by
- Nov 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and (2) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced: a. In the paint building, where spray painting of flammable liquids was conducted, and where non-explosion proof electrical wiring and components, such as 120 V outlets and switches, and an electric refrigerator, were within 10 feet of parts sprayed, an employee was not provided chemical hazard communication training which would include the physical hazards of chemicals such as, but not limited, explosion and fire hazards (note: comprehensive training would include both physical and health hazards, training on material safety data sheets including the more commonly used products, labeling, and non-routine tasks that might present a hazard). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Feb 21, 2013
- Abate by
- Nov 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a. A spray painter, using a half mask, cartridge respirator was not fit tested before being allowed to spray paint. (Note: the respiratory protection standard would also require training and medical evaluation.) Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Brooks Brothers Trailers, INC.
View Brooks Brothers Trailers, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336212)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338364839.