GETTYSBURG, PA —
OSHA Inspection: GETTYSBURG CONSTRUCTION CO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GETTYSBURG CONSTRUCTION CO in 114 CHAMBERSBURG STREET, GETTYSBURG, PA 17325 (NAICS 236116). OSHA activity number 338368053.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GETTYSBURG CONSTRUCTION CO
- Site address
- 114 CHAMBERSBURG STREET
- City
- GETTYSBURG
- State
- PA
- ZIP
- 17325
- Mailing
- 828 BIGLERVILLE ROAD, GETTYSBURG, PA 17325
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 18
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.405 A02 II B
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(B): Runs of open conductors used as temporary wiring branch circuits were located along the floor, and the conductors were not fastened at intervals of at least every 10 feet: (a) 114 CHAMBERSBURG STREET, GETTYSBURG, PA, GROUND FLOOR - The 110 volt romex branched circuit that was used to supply power to the temporary lighting that employees were using as a light source, was hanging loose and running across the ground, thereby exposing employee(s) to electrical shock injuries, on or about January 17, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.405 A02 II E
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: (a) 114 CHAMBERSBURG STREET, GETTYSBURG, PA, GROUND FLOOR - The employer did not ensure that the 110 volt temporary lighting was equipped with a protective cage to protect the lamp from accidental contact and/or damage, thereby exposing employees to electrical shock injuries, on or about January 17, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.405 A02 II F
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights were suspended by their electric cords when such lights and cords were not designed for suspension: (a) 114 CHAMBERSBURG STREET, GETTYSBURG, PA, GROUND FLOOR - Exposed temporary lighting was suspended by its own cord in a fashion it was not designed for, thereby exposing employees to electrical shock injuries, on or about January 17, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of 1926.502(k) developed and implemented: (a) 114 CHAMBERSBURG STREET, GETTYSBURG, PA, SECOND FLOOR - The employer did not provide fall protection for employees constructing the second floor of an apartment building, thereby exposing employees to fall hazards ranging from approximately eleven (11) feet to approximately fourteen (14) feet to the ground below, on or about January 17, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1926.1053 B04
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed: (a) 114 CHAMBERSBURG STREET, GETTYSBURG, PA, SECOND FLOOR - Employee(s) worked from six (6) foot fiberglass step ladders while the ladders were in the closed position and leaned up against a wall near the unprotected edge of a second floor structure, thereby exposing employee(s) to an approximate fourteen (14) foot fall hazard to the ground below, on or about January 17, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1926.1053 B13
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) 114 CHAMBERSBURG STREET, GETTYSBURG, PA, SECOND FLOOR - Employees worked from the top and also the top step of six (6) foot fiberglass stepladders, thereby exposing employees to fall injuries, on or about January 17, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.416 E02
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(2): Extension cords were fastened with staples, hung from nails, or suspended by wire: (a) 114 CHAMBERSBURG STREET, GETTYSBURG, PA, GROUND FLOOR - Employee(s) used 110 volt temporary lighting while it was plugged into an orange extension cord, where the extension cord was strung across the room and hung from a nail on the East wall, thereby exposing employee(s) to electrical shock injuries, on or about January 17, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Gettysburg Construction CO
View Gettysburg Construction CO's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338368053.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.