On , OSHA opened a planned safety inspection of MILBANK MANUFACTURING COMPANY in 4801 DERAMUS, KANSAS CITY, MO 64120 (NAICS 332439). OSHA activity number 338371479.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MILBANK MANUFACTURING COMPANY
- Site address
- 4801 DERAMUS
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64120
- Mailing
- 4801 DERAMUS, KANSAS CITY, MO 64120
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332439
- Employees
- 287
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.151 C
- Issued
- Mar 29, 2013
- Abate by
- May 3, 2013
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) On January 17th, 2013 employees of Milbank Manufacturing that added water to floor sweeper batteries in the production area were exposed to contact with corrosive chemicals when there was not an eye wash station in the proximity.
Recent events (3)
- — F (S) $0
- — C (S) $4000
- — Z (S) $4000
1910.212 A02
- Issued
- Mar 29, 2013
- Abate by
- May 3, 2013
- Penalty
- Initial $4,000 · Current $4,000
General-duty citation text
29 CFR 1910.212(a)(2): Machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points and rotating parts: (a) On January 17th, 2013, employees of Milbank Manufacturing were exposed to caught in hazards from exposed rotating parts on a DoAll drill press located in the maintenance area. The guard for the machine was lying on the ground behind the machine. (b) On January 17th, 2013, employees of Milbank Manufacturing were exposed to caught in hazards from exposed rotating parts of a Procunier Drill press in the top cell area.
Recent events (3)
- — F (S) $4000
- — C (S) $4000
- — Z (S) $4000
1910.215 B09
- Issued
- Mar 29, 2013
- Abate by
- May 3, 2013
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) On January 17th, 2013 employees of Milbank Manufacturing working in the maintenance area were exposed to struck by and caught in hazards when the tongue guard was not properly adjusted to one fourth inch or less.
Recent events (3)
- — F (O) $3000
- — C (S) $3000
- — Z (S) $3000
1910.303 B02
- Issued
- Mar 29, 2013
- Abate by
- Jul 2, 2013
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On January 17th, 2013 employees of Milbank Manufacturing were exposed to contact with electrical current hazards when flexible cords were used throughout the facility for permanent wiring. Many of the cords were also permanently affixed to various parts the building with zip ties increasing the likelihood of damage to the cord insulation.
Recent events (3)
- — F (S) $0
- — C (S) $3000
- — Z (S) $3000
1910.303 G02
- Issued
- Mar 29, 2013
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1) Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. (a) On January 17th, 2013 employees of Milbank Manufacturing were exposed to contact with electrical current and fire hazards when one 120 VAC and one 480 VAC electrical panels were blocked by machinery and other various materials in the maintenance and welding areas.
Recent events (3)
- — F (S) $0
- — C (S) $3400
- — Z (S) $3400
More inspections at Milbank Manufacturing Company
View Milbank Manufacturing Company's full OSHA safety record →
More inspections in this industry (NAICS 332439)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338371479.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.