Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TEXASITE LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TEXASITE LLC. in HAWKS PRAIRIE BLVD SNOWY EGRET DRIVE, FULSHEAR, TX 77441 (NAICS 237110). OSHA activity number 338376635.

Watch Texasite LLC. — free Get an email when a new federal OSHA severe-injury report for Texasite LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
TEXASITE LLC.
Site address
HAWKS PRAIRIE BLVD SNOWY EGRET DRIVE
City
FULSHEAR
State
TX
ZIP
77441
Mailing
3486 COUNTRY CLUB BLVD, MONTGOMERY, TX 77356
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees.    At the job site, on January 17, 2013, an employee was installation of 48 inch pipe and did not have a safe means of egress in a trench that was approximately 11 feet in depth, exposing the employee to struck-by and caught between hazards.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.651 K02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety.     At the job site, on January 17, 2013, the competent person did not remove an unprotected employee from an excavation that was approximately 11 feet in depth when there were evidence of cave in such as fission and cracks, exposing the employee to struck-by and engulfment hazards.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).    At the job site, on January 17, 2013, an employee was installation of 48 inch pipe without adequate protection system in a trench that was approximately 11 feet in depth, exposing the employee to struck-by and engulfment hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338376635.