OSHA Inspection: AMUNEAL MANUFACTURING CORP.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AMUNEAL MANUFACTURING CORP. in 4737 DARRAH STREET, PHILADELPHIA, PA 19124 (NAICS 238390). OSHA activity number 338378037.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amuneal Manufacturing Corp. — free Get an email when a new federal OSHA severe-injury report for Amuneal Manufacturing Corp. is published. One employer, no account, unsubscribe in one click.
Site address
4737 DARRAH STREET
City
PHILADELPHIA
State
PA
ZIP
19124
Mailing
4737 DARRAH STREET, PHILADELPHIA, PA 19124
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
78
Ownership type
A

4 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 26, 2013
Abate by
Aug 31, 2013
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.134(c)(2)(ii):     The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    a) An employee, (Welder) while TIG welding MuMetal, was provided and voluntarily donned a half face tight-fitting elastomeric North 7700 30M respirator. The employee did not develop a written respiratory protection program to ensure that the employees were not exposed to health hazards associated with the respirator. On or about February 6, 2013.     b) An employee, (Finisher) while spraying Permalac Clearcoat onto manufactured metal products, was provided with and voluntarily wore a half face tight-fitting elastomeric 3M 7503 respirator. The employer did not develop a written respiratory protection program to ensure that the employees were not exposed to health hazards associated with the use of the respirator. On or about February 6, 2013.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.134 E01

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 26, 2013
Abate by
Aug 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1):     The employer did not provide a medical evaluation to determine the employees ability to use a respirator before the employee voluntarily wore a tight-fitting elastomeric respirator the workplace:    a) An employee, (Welder) while TIG welding MuMetal, was provided and voluntarily donned a half face tight-fitting elastomeric North 7700 30M respirator. The employer did not provide the employee with a medical evaluation to ensure that the employee was medically fit to wear the respirator. On or about February 6, 2013.     b) An employee, (Finisher) while spraying Permalac Clearcoat onto manufactured metal products, was provided with and voluntarily wore a half face tight-fitting elastomeric 3M 7503 respirator. The employer did not provide the employee with a medical evauation to ensure that the employee was medically fit to wear the respirator On or about February 6, 2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 26, 2013
Abate by
Jul 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i):     Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:    a) An employee, (Welder) while TIG welding MuMetal, was provided and voluntarily donned a half face tight-fitting elastomeric North 7700 30M respirator. The employer did not ensure that the respirator was stored appropriately as the employee left the respirator lying uncovered on the workbench when not in use. On or about February 6, 2013.     b) An employee, (Finisher) while spraying Permalac Clearcoat onto manufactured metal products, was provided with and voluntarily wore a half face tight-fitting elastomeric 3M 7503 respirator. The employer did not ensure that the respirator was stored appropriately as the employee left the respirator uncovered on top of rags in the finishing area where hoses were used to remove chemicals from metal products. On or about February 6, 2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 4 exposed
Issued
Jun 26, 2013
Abate by
Jul 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i):     Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    a) Amuneal Manufacturing, Inc.: Employees (Welders and Grinders) voluntarily donned 3M 8511 N95 filtering facepiece respirators while welding and grinding on metals. The employer did not provide the employees with the information found in Appendix D of the respiratory protection standard. On or about February 6, 2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338378037.