FORT PAYNE, AL —
OSHA Inspection: CROWNE MANAGEMENT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CROWNE MANAGEMENT, LLC in 403 13TH ST NW, FORT PAYNE, AL 35967 (NAICS 623311). OSHA activity number 338395445.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CROWNE MANAGEMENT, LLC
- Site address
- 403 13TH ST NW
- City
- FORT PAYNE
- State
- AL
- ZIP
- 35967
- Mailing
- 403 13TH STREET NW, FORT PAYNE, AL 35967
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 623311
- Employees
- 150
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 19, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $1,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 01/21/2013 - The employer had not developed procedures for equipment and machinery such as but not limited to industrial washers, dryer, air conditioners, dishwashers, and stoves.
Recent events (2)
- — I (O) $600
- — Z (O) $1000
1910.147 C06 I
- Issued
- Feb 19, 2013
- Abate by
- Mar 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) On or about 01/21/2013 - The employer did not conduct an annual inspection of the energy control procedures.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1030 F02 I
- Issued
- Feb 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1030(f)(2)(i): Hepatitis B vaccination was not made available after the employee had received the training required in 29 CFR 1910.1030(g)(2)(vii)(I) or within 10 working days of initial assignment to employees who had occupational exposure: (a) On or about 01/21/2013 - An employee was not given the hepatitis B vaccination. Seven months have passed since the employee received training and was offered and accepted the hepatitis B vaccination.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Crowne Management, LLC
View Crowne Management, LLC's full OSHA safety record →
More inspections in this industry (NAICS 623311)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338395445.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.