On , OSHA opened a referral safety inspection of FALL RIVER DEACONESS HOME, INC. in 603 ROCK STREET, FALL RIVER, MA 02720 (NAICS 623990). OSHA activity number 338396641.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fall River Deaconess Home, INC. — free Get an email when a new federal OSHA severe-injury report for Fall River Deaconess Home, INC. is published. One employer, no account, unsubscribe in one click.
Site address
603 ROCK STREET
City
FALL RIVER
State
MA
ZIP
02720
Mailing
PO BOX 2118, FALL RIVER, MA 02722
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623990
Employees
95
Ownership type
A

6 citations on file for this inspection.

1910.213 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut      Location: Garage behind 309 French Street, Fall River, MA    The table saw did not have an automatically adjusting hood enclosing the portion of the saw above the table and above the material being cut.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.213 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
Jun 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:   LOCATION:  Garage behind 309 French Street, Fall River, MA   The maintenace employees at the facility use the table saw to cut various wood products, and the blade is not equipped with a spreader to ensure that the wood is not thrown back at them.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
Jun 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:   Location: 309 French Street, Fall River, MA  Employees use a table saw without a kickback device, which is necessary to prevent wood material from being thrown back at the operator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
Jun 5, 2013
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery was not adjusted close to the wheel with a maximum opening of one eighth inch:  Location: Garage behind 309 French Street, Fall River, MA.  Employees operated a bench grinder with a work rest adjusted such that the maximum opening between the rest and the wheel was more than one eighth of an inch.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.242 B

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
Jun 5, 2013
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. in case of being dead-ended.  Location:  Garage behind 603 Rock Street, Fall River, MA  A compressed air gun used for cleaning purposes did not have a method to reduce the pressure to below 30 p.s.i. if dead-ended.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.1030 C01 I

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Apr 18, 2013
Abate by
Jun 5, 2013
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.1030(c)(1)(i): The employer having employee(s) with occupational exposure did not establish a written Exposure Control Plan designed to eliminate or minimize employee exposure:   Location:  Clinics at facility.  The employer did not develop a written Exposure Control Plan in the worksite where there is the potential for occupational exposure to bloodborne pathogens via the administration of various intravenous mediciines such as flu vaccinations, Hepatitis B vaccinations, and the birth control medicine Depo-Provera.  Such plan should include:  1) An exposure determination for each job category 2) A means of complying with engineering and work practice controls outlined in Section d of the Standard 3) Annual documentation of consideration of new safe needle devices, including solicitation of input from non-managerial stafff 4) Records of training and dates of each employee's HBV vaccination and/or  HBV vaccination declination forms
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338396641.