LIVERPOOL, NY —
OSHA Inspection: LIVERPOOL LUMBER CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LIVERPOOL LUMBER CO., INC. in 201 N. WILLOW STREET, LIVERPOOL, NY 13088 (NAICS 444190). OSHA activity number 338397235.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LIVERPOOL LUMBER CO., INC.
- Site address
- 201 N. WILLOW STREET
- City
- LIVERPOOL
- State
- NY
- ZIP
- 13088
- Mailing
- 201 N. WILLOW STREET, LIVERPOOL, NY 13088
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 18
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.22 D02
- Issued
- Feb 14, 2013
- Abate by
- Mar 22, 2013
- Penalty
- Initial $1,700 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(d)(2): Loads greater than that approved by the building official were placed or permitted to be placed on a floor or roof or other structure: a) Pine Barn, on or about 1/23/13: A horizontal floor support for the storage mezzanine, two collar tie roof supports and two roof beams were cracked in the building. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $1700
- — Z (S) $1700
1910.23 A01
- Issued
- Feb 14, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $1,020 · Current $750 Reduced
General-duty citation text
29 CFR 1910.23(a)(1): Stairway floor opening was not guarded by a standard railing constructed in accordance with paragraph (e) of this section: a) Pine Barn, on or about 1/23/13: Stairway floor opening on the mezzanine was not provided with midrails. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $750
- — C (S) $1020
- — Z (S) $1020
1910.23 C01
- Issued
- Feb 14, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): a) Outside Pine Barn, cedar and insulation storage area, on or about 1/23/13: Open sided floor at the insulation storage level, ten feet from ground level was not provided with a midrail in one section. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.24 F
- Issued
- Feb 14, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $1,020 · Current $750 Reduced
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: a) Pine Barn, on or about 1/23/13: A fixed stairway with ten risers to the storage mezzanine was not uniform throughout the flight in that the entire stairway was leaning to the right, had broken steps and steps were separating from their cleats. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $750
- — C (S) $1020
- — Z (S) $1020
1910.157 G02
- Issued
- Feb 14, 2013
- Abate by
- Mar 22, 2013
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) At the establishment, on or about 1/23/13: Training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting. *ABATEMENT NOTE: The employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38 and 29 CFR 1910.39 which includes the evacuation requirements of 29 CFR 1910.157(b): Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $1020
- — Z (S) $1020
1910.212 A01
- Issued
- Feb 14, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $1,020 · Current $750 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) In the Shop, on or about 1/23/13: Rotating chuck on a Buffalo drill press was not guarded. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $750
- — C (S) $1020
- — Z (S) $1020
1910.213 H01
- Issued
- Feb 14, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock being cut: a) In the Shop, on or about 1/23/13: The lower blade guard on the left side of a Skil radial arm saw, Model #45009, was up out of position and would not automatically adjust itself. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $750
- — C (S) $1700
- — Z (S) $1700
1910.213 H04
- Issued
- Feb 14, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: a) In the Shop, on or about 1/23/13: A Skil radial arm saw, Model #45009, would not return to the starting position when pulled out. Abatement certification must be submitted for this item.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 444190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338397235.