Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JASPER WYMAN & SON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JASPER WYMAN & SON in 178 MAIN STREET, CHERRYFIELD, ME 04622 (NAICS 311411). OSHA activity number 338402837.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jasper Wyman & SON — free Get an email when a new federal OSHA severe-injury report for Jasper Wyman & SON is published. One employer, no account, unsubscribe in one click.
Establishment
JASPER WYMAN & SON
Site address
178 MAIN STREET
City
CHERRYFIELD
State
ME
ZIP
04622
Mailing
P. O. BOX 100, MILBRIDGE, ME 04658
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311411
Employees
79
Ownership type
A

7 citations on file for this inspection.

1910.176 B

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2013
Abate by
Feb 15, 2013
Penalty
Initial $4,500 · Current $3,150 Reduced
29 CFR 1910.176(b):     Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.      Storage Area - The pallets of box cartons were not stacked and limited in height so that they were stable and secure against sliding and collapse.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $4500

1910.212 A01

Serious Gravity 10 8 instances 3 exposed
Issued
Feb 5, 2013
Abate by
Feb 25, 2013
Penalty
Initial $6,300 · Current $4,410 Reduced
29 CFR 1910.212(a)(1):   Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.      a)   Maintenance Dept. - The Grizzly drill press was not provided to protect the operator from the rotating chuck and drill bit.    b)   30 Pound Packing Line - The infeed and outfeed of the transfer conveyor had inrunning nip points between the chain and sprocket that were not guarded.    c) Inspection Room - The feed conveyor for the inspection lines had inrunning nip points and rotating spoke sprocket that were not guarded.    d) Inspection Room - The inspection lines had rotating spoke sprockets or solid sprockets with ribs at the outfeed end of the conveyor that were not guarded.    e) Inspection Room -  The infeed end of the discharge conveyor had inrunning nip points and rotating solid sprockets with ribs that were not guarded.
Recent events (2)
  • — I (S) $4410
  • — Z (S) $6300

1910.219 C02 I

Serious Gravity 10 11 instances 5 exposed
Issued
Feb 5, 2013
Abate by
Feb 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i):   All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.    a) 30 Pound Packing Line - The exposed rotating shafts at each end of the conveyor were not enclosed.    b) Uncuffer Feed Conveyor - The two horizontal rotating shafts were not enclosed.    c) Inspection Room - The horizontal rotating shaft for the feed conveyor to the inspection lines was not enclosed.    d) Inspection Room - The horizontal rotating shaft for the discharge conveyor was not enclosed.    e) Inspection Room - The horizontal rotating shafts for the outfeed end of the inspection lines were not enclosed.    e) Metal Detector Table - The horizontal rotating shaft for the outfeed end was not enclosed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F01

Serious Gravity 10 4 instances 1 exposed
Issued
Feb 5, 2013
Abate by
Feb 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(1):   Sprocket(s) and chain(s) shall be guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii):     30 Pound Packing Line - The rotating spoked sprockets used to advance the two conveyor chains were not enclosed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E02

Other-than-serious 2 instances 2 exposed
Issued
Feb 5, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2):   Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.    In the Plant - Portable fire extinguishers located at stations 9 & 10 had not been visually inspected monthly since November 2012.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 1 exposed
Issued
Feb 5, 2013
Abate by
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2):    Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.    Packing Area - The stainless steel electrical panel was not marked to indicate its purpose.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.335 B01

Other-than-serious 1 instance 1 exposed
Issued
Feb 5, 2013
Abate by
Feb 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.335(b)(1):   Safety signs and tags. Safety signs, safety symbols, or accident prevention tags shall be used where necessary to warn employees about electrical hazards which may endanger them, as required by 1910.145.    Packing Area - The new electrical panel did not have an arc flash warning sign.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Jasper Wyman & SON's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338402837.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.