FRANKSVILLE, WI —
OSHA Inspection: SPECIALTY TAPES MANUFACTURING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SPECIALTY TAPES MANUFACTURING, LLC in 4221 COURTNEY RD, FRANKSVILLE, WI 53126 (NAICS 322222). OSHA activity number 338420839.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPECIALTY TAPES MANUFACTURING, LLC
- Site address
- 4221 COURTNEY RD
- City
- FRANKSVILLE
- State
- WI
- ZIP
- 53126
- Mailing
- 4221 COURTNEY RD, FRANKSVILLE, WI 53126
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322222
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C06 I
- Issued
- May 22, 2013
- Abate by
- Jul 10, 2013
- Penalty
- Initial $3,273 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) The employer did not conduct a periodic inspection to ensure employees are following steps in the energy-control procedures, employees involved know their responsibilities under the procedures, and the procedure was adequate to provide the necessary protection, and what changes, if any, are needed.
Recent events (2)
- — I (O) $0
- — Z (S) $3273
1910.212 A01
- Issued
- May 22, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $3,273 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) The Siat #1 (PSR00021) had unguarded inrunning nip points where two rollers were positioned on top of each other. This exposed employees to caught in hazards. (b) The Siat #2 (PSR00022) had unguarded inrunning nip points where two rollers were positioned on top of each other. This exposed employees to caught in hazards. (c) The Siat #3 (PSR00023) had unguarded inrunning nip points where two rollers were positioned on top of each other. This exposed employees to caught in hazards.
Recent events (2)
- — I (S) $2300
- — Z (S) $3273
1910.146 C01
- Issued
- May 22, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: (a) The employer did not evaluate for permit required confined space prior to the inspection for spaces such as but not limited to: prime oven, ovens 1-4, and oxidizer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.146 C04
- Issued
- May 22, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: (a) The employer did not develop a written permit required confined space program prior to the inspection for spaces such as but not limited to: prime oven, ovens 1-4, and oxidizer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C01
- Issued
- May 22, 2013
- Abate by
- Jul 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) The employer did not maintain a written lockout/tagout program for the periodic inspection which described in detail necessary to ensure a safe and continuing lockout process. The energy control program did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be established to control all potentially hazardous energy sources.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Specialty Tapes Manufacturing, LLC
View Specialty Tapes Manufacturing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 322222)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338420839.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.