Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SPECIALTY TAPES MANUFACTURING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPECIALTY TAPES MANUFACTURING, LLC in 4221 COURTNEY RD, FRANKSVILLE, WI 53126 (NAICS 322222). OSHA activity number 338420839.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Specialty Tapes Manufacturing, LLC — free Get an email when a new federal OSHA severe-injury report for Specialty Tapes Manufacturing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4221 COURTNEY RD
City
FRANKSVILLE
State
WI
ZIP
53126
Mailing
4221 COURTNEY RD, FRANKSVILLE, WI 53126
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322222
Employees
40
Ownership type
A

5 citations on file for this inspection.

1910.147 C06 I

Other-than-serious 10 instances 4 exposed
Issued
May 22, 2013
Abate by
Jul 10, 2013
Penalty
Initial $3,273 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a)  The employer did not conduct a periodic inspection to ensure employees are following steps in the energy-control procedures, employees involved know their responsibilities under the procedures, and the procedure was adequate to provide the necessary protection, and what changes, if any, are needed.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3273

1910.212 A01

Serious Gravity 5 4 instances 4 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $3,273 · Current $2,300 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a)  The Siat #1 (PSR00021) had unguarded inrunning nip points where two rollers were positioned on top of each other.  This exposed employees to caught in hazards.  (b)  The Siat #2 (PSR00022) had unguarded inrunning nip points where two rollers were positioned on top of each other.  This exposed employees to caught in hazards.  (c)  The Siat #3 (PSR00023) had unguarded inrunning nip points where two rollers were positioned on top of each other.  This exposed employees to caught in hazards.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $3273

1910.146 C01

Other-than-serious 3 instances 3 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: (a)  The employer did not evaluate for permit required confined space prior to the inspection for spaces such as but not limited to:  prime oven, ovens 1-4, and oxidizer.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.146 C04

Other-than-serious 3 instances 3 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  (a)  The employer did not develop a written permit required confined space program prior to the inspection for spaces such as but not limited to:  prime oven, ovens 1-4, and oxidizer.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C01

Other-than-serious 1 instance 4 exposed
Issued
May 22, 2013
Abate by
Jul 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a)  The employer did not maintain a written lockout/tagout program for the periodic inspection which described in detail necessary to ensure a safe and continuing lockout process.  The energy control program did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be established to control all potentially hazardous energy sources.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Specialty Tapes Manufacturing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338420839.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.