APALACHIN, NY —
OSHA Inspection: A J LETO AND SONS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A J LETO AND SONS INC. in 7666 ROUTE 434 QUALITY INN, APALACHIN, NY 13732 (NAICS 236116). OSHA activity number 338422033.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A J LETO AND SONS INC.
- Site address
- 7666 ROUTE 434 QUALITY INN
- City
- APALACHIN
- State
- NY
- ZIP
- 13732
- Mailing
- 1539 UNION CENTER MAIN HWY, ENDICOTT, NY 13760
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.154 B02
- Issued
- Feb 19, 2013
- Penalty
- Initial $765 · Current $0 Reduced
General-duty citation text
29 CFR 1926.154(b)(2): Temporary heating devices, which are listed for installation with lesser clearances than specified in Table F-4, may be installed in accordance with their approval. TABLE F-4 ________________________________________________________________ Minimum clearance, (inches) ____________________________ Heating appliances Chimney Sides Rear Connector ___________________________________ _______ _______ ____________ Room heater, circulating type...... 12 12 18 Room heater, radiant type.......... 36 36 18 ___________________________________ _______ _______ ____________ a) New Hotel Construction Site 7666 Hwy 434, Apalachin, NY - On or about 23 January, 2013 - Employees were working on the second floor while a temporary heating device was in operation within 36 inches of combustible materials.
Recent events (2)
- — I (S) $0
- — Z (S) $765
1926.404 B01 III C
- Issued
- Feb 19, 2013
- Penalty
- Initial $1,360 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired. a) New Hotel Construction Site 7666 Hwy 434, Apalachin, NY - On or about 23 January, 2013 - Employees were plugging extension cords into a 50 Amp power center that had a damaged cord attached.