Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FIBERGLASS SPECIALTIES

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of FIBERGLASS SPECIALTIES in H STATE 1-36-25H WILLIAMS COUNTY ROAD 7 & 72ND STREET, GRENORA, ND 58845 (NAICS 213112). OSHA activity number 338423031.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fiberglass Specialties — free Get an email when a new federal OSHA severe-injury report for Fiberglass Specialties is published. One employer, no account, unsubscribe in one click.
Site address
H STATE 1-36-25H WILLIAMS COUNTY ROAD 7 & 72ND STREET
City
GRENORA
State
ND
ZIP
58845
Mailing
7600 HIGHWAY 2 EAST, MINOT, ND 58701
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
35
Ownership type
A

7 citations on file for this inspection.

1910.106 B06

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 10, 2013
Abate by
Jul 15, 2013
Penalty
Initial $5,390 · Current $3,773 Reduced
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition.  Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat:    (a) On or about January 18, 2013, and at times prior, for employees performing "glassing" work, where styrene resin is mixed with a catalyst and applied to fiberglass sheets in order to replace leaking fittings inside fiberglass tanks and an L.B. White Tradesman kerosene heater with an open flame was used in order to heat the materials so that they "kick," i.e., cure and harden, in fiberglass tanks at the H State well 1-36-25H and other oil and gas locations throughout North Dakota.
Recent events (2)
  • — I (S) $3773
  • — Z (S) $5390

1910.146 D03 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 10, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,390 · Current $3,773 Reduced
29 CFR 1910.146(d)(3)(iv): Under the permit space program, the employer did not develop and implement the means, procedures, and practices necessary for safe permit entry operations, including, but not limited to, purging, inerting, flushing or ventilating the permit spaces as necessary to eliminate or control atmospheric hazards:    (a) On or about January 18, 2013, and at times prior, where a flammable atmosphere was allowed to develop while employees performed "glassing" work, whereby styrene resin is mixed with a catalyst and applied to fiberglass sheets in order to replace leaking fittings inside a fiberglass product water tank at the H State well 1-36-25H and other oil and gas locations throughout North Dakota.
Recent events (2)
  • — I (S) $3773
  • — Z (S) $5390

1910.146 D03 VI

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 10, 2013
Abate by
Jul 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(3)(vi): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit entry operations, including, but not limited to, verifying that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry:  (a) On or about January 18, 2013, and at times prior, where a flammable atmosphere was allowed to develop while employees performed "glassing" work, whereby styrene resin is mixed with a catalyst and applied to fiberglass sheets in order to make repairs inside a fiberglass product water tank at the H State well 1-36-25H and other oil and gas locations throughout North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 G03

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 10, 2013
Abate by
Sep 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(3): The employer did not provide training that established employee proficiency in the duties required by 29 CFR 1910.146, permit-required confined spaces, and did not introduce new or revised procedures, as necessary, for compliance:    (a) On or about January 18, 2013, and at times prior, for employees performing "glassing" work, whereby styrene resin is mixed with a catalyst and applied to fiberglass sheets in order to make repairs inside fiberglass tanks and an L.B. White Tradesman kerosene heater with an open flame was used in order to heat the materials so that they "kick," i.e., cure and harden, in fiberglass tanks at the H State well 1-36-25H and other oil and gas locations throughout North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 C

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 10, 2013
Abate by
Aug 12, 2013
Penalty
Initial $5,390 · Current $3,773 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    (a) On or about January 18, 2013, and at times prior, for employees involved in a tank explosion while performing "glassing" work, whereby styrene resin is mixed with a catalyst and applied to fiberglass sheets in order to make repairs inside fiberglass tanks, and where unapproved equipment was used at the H State well 1-36-25H near Grenora, North Dakota, and other oil and gas locations.
Recent events (2)
  • — I (S) $3773
  • — Z (S) $5390

1910.146 D09

Repeat Gravity 10 1 instance 2 exposed
Issued
Jul 10, 2013
Abate by
Sep 12, 2013
Penalty
Initial $10,780 · Current $7,546 Reduced
29 CFR 1910.146(d)(9): The employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue:    (a) On or about January 18, 2013, and at times prior, for employees involved in a tank explosion while performing "glassing" work, whereby styrene resin is mixed with a catalyst and applied to fiberglass sheets in order to make repairs inside fiberglass tanks, and an L.B. White Tradesman kerosene heater with an open flame was used to heat the materials so they would "kick," i.e., cure and harden, in a fiberglass product water tank at the H State well 1-36-25H near Grenora, North Dakota, and other oil and gas locations.    Note:  This company was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard which was contained in OSHA Inspection Number 111117, Citation 1, Item 3C, and was affirmed as a final order on July 17, 2012, with respect to a workplace located at 7600 Highway 2 East in Minot, North Dakota.
Recent events (2)
  • — I (R) $7546
  • — Z (R) $10780

1910.146 E01

Repeat Gravity 10 1 instance 2 exposed
Issued
Jul 10, 2013
Abate by
Jul 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit:  (a) On or about January 18, 2013, and at times prior, for employees involved in a tank explosion while performing "glassing" work, whereby styrene resin is mixed with a catalyst and applied to fiberglass sheets in order to make repairs inside fiberglass tanks, and an L.B. White Tradesman kerosene heater with an open flame was used to heat the materials so they would "kick," i.e., cure and harden, in a fiberglass product water tank at the H State well 1-36-25H near Grenora, North Dakota, and other oil and gas locations.  Note:  This company was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard which was contained in OSHA Inspection Number 111117, Citation 1, Item 3D, and was affirmed as a final order on July 17, 2012, with respect to a workplace located at 7600 Highway 2 East in Minot, North Dakota.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

View Fiberglass Specialties's full OSHA safety record →