CHICAGO, IL —
OSHA Inspection: QUALAWASH HOLDINGS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of QUALAWASH HOLDINGS, LLC in 803 EAST 120TH STREET, CHICAGO, IL 60628 (NAICS 562998). OSHA activity number 338445448.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALAWASH HOLDINGS, LLC
- Site address
- 803 EAST 120TH STREET
- City
- CHICAGO
- State
- IL
- ZIP
- 60628
- Mailing
- 803 EAST 120TH STREET, CHICAGO, IL 60628
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562998
- Employees
- 32
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 A03
- Issued
- Feb 14, 2013
- Abate by
- Apr 3, 2013
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.22(a)(3): To facilitate cleaning, every floor, working place, and passageway shall be kept free from protruding nails, splinters, holes, or loose boards. a. Metal Grating on Floor Drainage System for Bay's # 1, 2, 3, and 4 - On or about January 28, 2013, several sections of the metal grating system for the floor was not kept free from protruding metal pieces, missing grating sections, loose grating sections, and holes. Employees were thereby exposed to the hazards of slips, trips, and falls.
Recent events (2)
- — I (S) $1275
- — Z (S) $2550
1910.23 C01
- Issued
- Feb 14, 2013
- Abate by
- Apr 3, 2013
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides, a. Working Platform between Bay's # 1 and 2 - On or about January 28, 2013, employees were required to perform tank truck washing operations from a platform above 4 feet from the ground level. The west side section of the platform was not provided with a standard guard railing (missing top rail and mid rail). Employees were thereby exposed to fall hazards. b. Working Platform between Bay's # 3 and 4 - On or about January 28, 2013, employees were required to perform tank truck washing operations from a platform above 4 feet from the ground level. The west side section of the platform was not provided with a standard guard railing (missing top rail and mid rail). Employees were thereby exposed to fall hazards.
Recent events (2)
- — I (S) $1275
- — Z (S) $2550
1910.334 A02 I
- Issued
- Feb 14, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. a. Work Light Fixture for Bays # 3 and # 4 - On or about January 28, 2013, employees were required to utilize a portable work light for hazardous conditions (metal guard, 25 ') which had an extension cord plug that was missing its grounding pin. Employees were thereby exposed to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $2550
1910.305 B02
- Issued
- Feb 14, 2013
- Abate by
- Feb 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2): In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. a. Exterior Wall between Bay's # 1 & 2 and 3 & 4 - On or about January 28, 2013, the outlet box was not effectively closed or covered. Employees were thereby exposed to potential electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Qualawash Holdings, LLC
View Qualawash Holdings, LLC's full OSHA safety record →
More inspections in this industry (NAICS 562998)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338445448.