Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALAWASH HOLDINGS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of QUALAWASH HOLDINGS, LLC in 803 EAST 120TH STREET, CHICAGO, IL 60628 (NAICS 562998). OSHA activity number 338445448.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Qualawash Holdings, LLC — free Get an email when a new federal OSHA severe-injury report for Qualawash Holdings, LLC is published. One employer, no account, unsubscribe in one click.
Site address
803 EAST 120TH STREET
City
CHICAGO
State
IL
ZIP
60628
Mailing
803 EAST 120TH STREET, CHICAGO, IL 60628
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562998
Employees
32
Ownership type
A

4 citations on file for this inspection.

1910.22 A03

Serious Gravity 1 1 instance 30 exposed
Issued
Feb 14, 2013
Abate by
Apr 3, 2013
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.22(a)(3):     To facilitate cleaning, every floor, working place, and passageway shall be kept free from protruding nails, splinters, holes, or loose boards.    a. Metal Grating on Floor Drainage System for Bay's # 1, 2, 3, and 4 - On or about January 28, 2013, several sections of the metal grating system for the floor was not kept free from protruding metal pieces, missing grating sections, loose grating sections, and holes. Employees were thereby exposed to the hazards of slips, trips, and falls.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.23 C01

Serious Gravity 1 2 instances 6 exposed
Issued
Feb 14, 2013
Abate by
Apr 3, 2013
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.23(c)(1):     Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,    a. Working Platform between Bay's # 1 and 2 - On or about January 28, 2013, employees were required to perform  tank truck washing operations from a platform above 4 feet from the ground level. The west side section of the platform was not provided with a standard guard railing (missing top rail and mid rail). Employees were thereby exposed to fall hazards.    b. Working Platform between Bay's # 3 and 4 - On or about January 28, 2013, employees were required to perform tank truck washing operations from a platform above 4 feet from the ground level. The west side section of the platform was not provided with a standard guard railing (missing top rail and mid rail). Employees were thereby exposed to fall hazards.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.334 A02 I

Other-than-serious 1 instance 3 exposed
Issued
Feb 14, 2013
Abate by
Feb 27, 2013
Penalty
Initial $2,550 · Current $0 Reduced
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.    a. Work Light Fixture for Bays # 3 and # 4 - On or about January 28, 2013, employees were required to utilize a portable work light for hazardous conditions (metal guard, 25 ') which had an extension cord  plug that was missing its grounding pin. Employees were thereby exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2550

1910.305 B02

Other-than-serious 1 instance 30 exposed
Issued
Feb 14, 2013
Abate by
Feb 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2):     In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy.    a. Exterior Wall between Bay's # 1 & 2 and 3 & 4 - On or about January 28, 2013, the outlet box was not effectively closed or covered. Employees were thereby exposed to potential electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Qualawash Holdings, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338445448.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.