MANSFIELD, TX —
OSHA Inspection: RODCO-BRANDT MANUFACTURER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RODCO-BRANDT MANUFACTURER in 600 S. 2ND AVE, MANSFIELD, TX 76063 (NAICS 337122). OSHA activity number 338449036.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RODCO-BRANDT MANUFACTURER
- Site address
- 600 S. 2ND AVE
- City
- MANSFIELD
- State
- TX
- ZIP
- 76063
- Mailing
- 600 S. 2ND AVE, MANSFIELD, TX 76063
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337122
- Employees
- 62
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.157 C01
- Issued
- Mar 25, 2013
- Abate by
- Apr 22, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. On or about January 24, 2013, and times prior thereto, at the spray booth area, the employer did not ensure employees had clear access to the fire extinguisher at all times. The fire extinguisher was not readily accessible exposing employees to fire hazards.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.213 D01
- Issued
- Mar 25, 2013
- Abate by
- Apr 22, 2013
- Penalty
- Initial $4,900 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut. On or about January 24, 2013, and times prior thereto, in the shortage mill area, the employer did not ensure an adjustable guard was placed on the hand-fed cross cut table saw prior to employees utilizing the equipment to cut wooden material, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $4900
1910.213 P01
- Issued
- Mar 25, 2013
- Abate by
- Apr 22, 2013
- Penalty
- Initial $2,800 · Current $1,420 Reduced
General-duty citation text
29 CFR 1910.213(p)(1): Feed rolls of self-feed sanding machine(s) were not protected with semicylindrical guard to prevent the hands of the operator from coming in contact with the in-running rolls. On or about January 24, 2013, and times prior thereto, in the sanding area, employees using two floor mounted sanders that did not have guards attached were exposed to caught-by and struck-by hazards.
Recent events (2)
- — I (S) $1420
- — Z (S) $2800
1910.215 A04
- Issued
- Mar 25, 2013
- Abate by
- Apr 22, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work. On or about January 24, 2013, and times prior thereto, employees using a bench grinder that did not have the work rests installed were exposed to struck-by and caught-by hazards. a) In the tool room, delta bench grinder without work rest, and b) In the shortage mill area, delta bench grinder without work rest.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.215 B09
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel. On or about January 24, 2013, and times prior thereto, the employer did not ensure adjustable tongue guards were installed prior to operating grinders, exposing employees to struck-by flying objects: a) In the tool room, delta bench grinder without tongue guards, and b) In the shortage mill area, delta bench grinder without tongue guards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Mar 25, 2013
- Abate by
- Apr 22, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. On or about January 24, 2013, and times prior thereto, in the sanding area, employees using compressed air that was not reduced to less than 30 p.s.i. for cleaning purposes were exposed to eye and skin injuries.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.304 A02
- Issued
- Mar 25, 2013
- Abate by
- Apr 22, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity. On or about January 24, 2013, and times prior thereto, at the dry oven section, three electrical outlets had reverse polarity, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 B01
- Issued
- Mar 25, 2013
- Abate by
- Apr 22, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed. On or about January 24, 2013, and times prior thereto, at the sanding area, the electrical box used for the floor sander was missing a knock-out plug, exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 G01 IV A
- Issued
- Mar 25, 2013
- Abate by
- Apr 22, 2013
- Penalty
- Initial $2,800 · Current $1,640 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. On or about January 24, 2013, and times prior thereto, at the dry oven section, three extension cords were utilized as fixed wiring for the dry oven cooling fans exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1640
- — Z (S) $2800
More inspections in this industry (NAICS 337122)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338449036.