SEATTLE, WA —
OSHA Inspection: COAST GUARD BASE SEATTLE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COAST GUARD BASE SEATTLE in 1519 ALASKA WAY SO., SEATTLE, WA 98134 (NAICS 926120). OSHA activity number 338459241.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COAST GUARD BASE SEATTLE
- Site address
- 1519 ALASKA WAY SO.
- City
- SEATTLE
- State
- WA
- ZIP
- 98134
- Mailing
- 1519 ALASKAN WAY SO, SEATTLE, WA 98134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 926120
- Employees
- 62
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 13, 2013
- Abate by
- Apr 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Facility engineering old paint shop, South Bend Lathe GS 26 did not have a chuck guard.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Feb 13, 2013
- Abate by
- Mar 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Facility engineering welding shop Clark Electric bench grinder tongue guard had a 3/4 inch gap between the guard and the wheel.
Recent events (1)
- — Z (S) $0
1910.134 C02 II
- Issued
- Feb 13, 2013
- Abate by
- Apr 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator: (a) Facility engineering welding shop, employer did not ensure that welder was physically capable of wearing a Power Air Purifying Respirator welding hood prior to allowing voluntary use.
Recent events (1)
- — Z (O) $0
1910.303 B02
- Issued
- Feb 13, 2013
- Abate by
- Mar 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Medical Admin break room a re-locatable power tap rated for 15 amps was use to plug in a GE refrigerator and an Oasis hot/cold water dispenser, with a total amp draw of 16.7amps.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 926120)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338459241.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.