CAMANCHE, IA —
OSHA Inspection: ARTCO FLEETING SERVICES (ADM LOGISTICS)
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ARTCO FLEETING SERVICES (ADM LOGISTICS) in 1325 N. WASHINGTON BLVD, CAMANCHE, IA 52730 (NAICS 488390). OSHA activity number 338464043.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARTCO FLEETING SERVICES (ADM LOGISTICS)
- Site address
- 1325 N. WASHINGTON BLVD
- City
- CAMANCHE
- State
- IA
- ZIP
- 52730
- Mailing
- 1425 N. WASHINGTON BLVD, CAMANCHE, IA 52730
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488390
- Employees
- 1200
- Ownership type
- A
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 16, 2013
- Penalty
- Initial $4,675 · Current $4,675
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of unintentional start up of metal cutting saws: American National Standard B11.10-1974--Safety Requirements for the Construction, Care, and Use of Metal Sawing Machines, paragraph 4.2.3.4: In the event of an interruption in the electrical power supply, the machine shall not restart automatically when power is restored: National Fire Protection Association 79 - 2002--Electrical Standards for Industrial Machinery, paragraph 7.5.3: Upon restoration of the voltage or upon switching on the incoming supply, automatic or unintentional restarting of the machine shall be prevented when such a restart can cause a hazardous condition: (a) In the Maintenance Shop, the on/off switch for the Wells bandsaw is a push lock in type, which would leave the circuit open in the event of power disruption and the saw could automatically restart with the restoration of the interrupted power supply. Among other methods, feasible and acceptable abatement means to correct this hazard include, but are not limited to: (1) Plug an anti-restart device between the power supply receptacle and the power cord of the band saw. (2) Use magnetic motor starter devices to provide anti-restart protection. DISCLAIMER: (1) The employer is not limited to the abatement method(s) suggested by OSHA. (2) The employer is responsible for selecting and implementing an effective abatement method.
Recent events (2)
- — I (S) $4675
- — Z (S) $4675
1910.101 B
- Issued
- Apr 16, 2013
- Penalty
- Initial $4,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders or portable tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: (a) In the Maintenance Shop, compressed gas cylinders were not secured, in accordance with the Compressed Gas Association Pamphlet P-1-1965 and were free standing. The cylinders were not protected from being knocked over.
Recent events (2)
- — I (S) $0
- — Z (S) $4675
1910.157 C01
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $3,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): 29 CFR 1910.157(c)(1): Portable Fire Extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) In the Maintenance Shop, a portable fire extinguisher was sitting on the floor next to a support beam and was unmounted.
Recent events (2)
- — I (S) $0
- — Z (S) $3300
1910.212 A03 II
- Issued
- Apr 16, 2013
- Penalty
- Initial $4,675 · Current $2,805 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) In the Maintenance Shop, the Wells bandsaw guard was not designed and constructed to protect the operator from unused portions of the blade during operation.
Recent events (2)
- — I (S) $2805
- — Z (S) $4675
1910.303 B02
- Issued
- Apr 16, 2013
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. (a) In the Maintenance Shop, a Relocatable Power Tap (RPTs), power strip, was used to supply power for fluorescent lighting and to power tools, such as Black and Decker JS500 jigsaw, creating a fire hazard for employees.
Recent events (2)
- — I (S) $0
- — Z (S) $2550
1910.304 G05
- Issued
- Apr 16, 2013
- Penalty
- Initial $0 · Current $2,550
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:(a)(LOCATION)(IDENTIFY EQUIPMENT AND CONDITION(S))(STATE HAZARD(S) TO EMPLOYEE(S)) (a) In the Maintenance Shop, a Relocatable Power Tap (RPTs), power strip, had an open ground creating a potential shock hazard and was used to supply power for fluorescent lighting and to power tools, such as Black and Decker JS500 jigsaw.
Recent events (2)
- — I (S) $2550
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Apr 16, 2013
- Penalty
- Initial $3,825 · Current $3,825
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: (a) In the Maintenance Shop, a Relocatable Power Tap (RPTs), power strip, was used to provide power for fluorescent lighting and to power hand tools, such as Black and Decker JS500 jigsaw, in place of fixed wiring.
Recent events (2)
- — I (O) $3825
- — Z (S) $3825
1910.305 G01 IV D
- Issued
- Apr 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: (a) In the Maintenance Shop, a Relocatable Power Tap (RPTs), power strip, was attached to a structural support as it was used to provide power for fluorescent lighting and to power hand tools, such as Black and Decker JS500 jigsaw, in place of fixed wiring.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Apr 16, 2013
- Penalty
- Initial $2,295 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) In the Maintenance Shop, a bandsaw had a flexible power cord that was pulled from the electrical control housing creating a shock hazard to employees.
Recent events (2)
- — I (S) $0
- — Z (S) $2295
1915.56 B01
- Issued
- Apr 16, 2013
- Penalty
- Initial $2,805 · Current $2,805
General-duty citation text
29 CFR 1915.56(b)(1): Arc welding and cutting cables were not completely insulated. (a) On the drydock, the arc welding cables for the Big Blue 400D (KF976344) diesel welder were damaged and were not completely insulated. The welder was used by employees to cut off the old rubber pads at the bow (front) of the Saratoga.
Recent events (2)
- — I (O) $2805
- — Z (S) $2805
1915.71 J03
- Issued
- Apr 16, 2013
- Penalty
- Initial $4,675 · Current $4,675
General-duty citation text
29 CFR 1915.71(j)(3): When rails were omitted, employees working more than 5 feet above solid surfaces were not protected by safety belts and life lines meeting the requirements of 1915.159 and 1915.160: (a) At the drydock barge, a five foot scaffold was used by employees to conduct work on the outer hull of the towboat. The end rail was not used as it did not fit under the vessel curvature leaving a gap between the hull of the vessel and the back of the scaffold that exposed employees to a fall hazard of 6 feet.
Recent events (2)
- — I (S) $4675
- — Z (S) $4675
1915.74 C02
- Issued
- Apr 16, 2013
- Penalty
- Initial $2,805 · Current $2,805
General-duty citation text
29 CFR 1915.74(c)(2): A safe walkway meeting the requirements of 29 CFR 1915.74(a)(7) was not provided to step safely to or from the wharf, float, barge, or river towboat. (a) At the drydock barge, safe access from the concrete pad barge was not provided. Employees were required to step across a space or gap of approximately 19 inches when accessing the dry dock barge to work on the Saratoga. (b) At the drydock barge, safe access from the crane barge was not provided. Employees were required to step across a space or gap of approximately 17 inches when accessing the dry dock barge to work on the Saratoga.
Recent events (2)
- — I (S) $2805
- — Z (S) $2805
1915.81 B01 II
- Issued
- Apr 16, 2013
- Penalty
- Initial $2,805 · Current $0 Reduced
General-duty citation text
29 CFR 1915.81(b)(1)(ii): The employer did not ensure that each walkway was clear of tools, materials, equipment, and other objects that create a hazard for employees. (a) At the concrete pad near the drydock, an unused winch system created a trip hazard for employees. Employees were required to step around or across the winch to access other work areas of the concrete pad.
Recent events (2)
- — I (S) $0
- — Z (S) $2805
More inspections in this industry (NAICS 488390)
More inspections in IA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338464043.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.