ALEXANDRIA, LA —
OSHA Inspection: FINE PRINT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FINE PRINT, LLC in 1220 MACARTHUR DR., ALEXANDRIA, LA 71303 (NAICS 323110). OSHA activity number 338466048.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FINE PRINT, LLC
- Site address
- 1220 MACARTHUR DR.
- City
- ALEXANDRIA
- State
- LA
- ZIP
- 71303
- Mailing
- 1220 MACARTHUR DR., ALEXANDRIA, LA 71303
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323110
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- May 6, 2013
- Penalty
- Initial $1,445 · Current $867 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. Production area: On or about January 16, 2013, the employer did not ensure that the rotating parts on an Advick offset press, model 9985, was covered with a guard. The offset press operator was exposed to the hazard of body parts coming in contact with the rotating parts.
Recent events (2)
- — I (S) $867
- — Z (S) $1445
1910.219 D01
- Issued
- May 6, 2013
- Abate by
- May 16, 2013
- Penalty
- Initial $1,700 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. Binding area: On or about January 16, 2013, the employer did not ensure that a guard was installed on the pulley assemblies of a Kluge automatic platen press, model #NB1211466. Employees were exposed to the hazard of coming in contact with rotating parts.
Recent events (2)
- — I (S) $1020
- — Z (S) $1700
1910.219 E03 I
- Issued
- May 6, 2013
- Abate by
- May 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section. Binding Area: On or about January 16, 2013, the employer did not ensure that the belt on a Kluge automatic platen press was guarded. Employees were exposed to the hazard of being caught in in-going nip points.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- May 6, 2013
- Abate by
- May 20, 2013
- Penalty
- Initial $1,700 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. Ricoh Digital Press Pro C 900 and 901: An electrical junction box (110 volts) was being used as a multiple outlet pendant box suspended from the ceiling. Employee(s) were exposed to the hazard of electrical shock.
Recent events (2)
- — I (S) $1020
- — Z (S) $1700
1910.157 C01
- Issued
- May 6, 2013
- Abate by
- May 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. Print shop along exit back wall: On or about January 16, 2013, the employer did not ensure that a portable fire extinguisher was mounted and equipped with a sign so that employee(s) could readily identify and locate it.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B05
- Issued
- May 6, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g., closet). Production Area (back of cutter): On or about January 16, 2013, the employer failed to ensure that a sign mark "not an exit" was placed above the door in back of the cutter machine.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 323110)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338466048.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.